• To ensure that cables are connected correctly, observe the labels on the cable and component connectors.
• Be sure that you have the latest firmware for the controllers, HBAs, and the expander card. To download the latest
firmware, see the Hewlett Packard Enterprise website (
http://www.hpe.com/support/hpesc).
• To enable SmartCache or CacheCade in the Smart Array controller, be sure that
Procedure
1.
Back up all server data.
2.
3.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4.
Do one of the following:
• Extend the server from the rack (
Extending the server from the rack).
• Remove the server from the rack (
Removing the server from the rack).
5.
Remove the access panel (
CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the
server in this manner results in improper airflow and improper cooling that can lead to thermal damage.
6.
7.
8.
Remove the expansion slot blank from the riser cage.
The primary PCIe riser cage is shown.
9.
Install the controller into the PCI riser cage, depending on the server configuration.
Hardware options installation