10. Install the air baffle (Installing the air baffle).
CAUTION: To avoid damaging the connectors, always install the air baffle into the server before installing the
riser cages.
11. Install the primary PCIe riser cage (Installing the primary PCIe riser cage).
12. Install the butterfly PCIe riser cage (Installing a butterfly PCIe riser cage).
13. Install the access panel (Installing the access panel).
14. Install the server into the rack (Installing the server into the rack).
15. Connect each power cord to the server.
16. Connect each power cord to the power source.
HPE Smart Storage Battery
The HPE Smart Storage Battery supports the following devices:
• HPE Smart Array SR controllers
• HPE Smart Array MR controllers
A single 96 W battery can support up to 24 devices.
After the battery is installed, it might take up to two hours to charge. Controller features requiring backup power are not
re-enabled until the battery is capable of supporting the backup power.
This server supports the 96 W HPE Smart Storage Battery with the 145 mm cable.
Installing a Smart Storage Battery
NOTE: System ROM and firmware messages might display "energy pack" in place of "Smart Storage Battery." Energy pack
refers to both HPE Smart Storage batteries and HPE Smart Storage Hybrid capacitors.
Hardware options installation
134