CAUTION: Before installing the riser cage into the server, be sure that the power cables are routed and
secured between the GPU card and the riser cage. Improper routing can result in damage to the cables and
connectors.
10. Install the riser cage.
11. Install the access panel (Installing the access panel).
12. Install the server into the rack (Installing the server into the rack).
13. Connect each power cord to the server.
14. Connect each power cord to the power source.
The installation is complete.
Installing the HPE NS204i-p NVMe OS Boot Device option
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment, remove power from
the server by removing the power cord. The front panel Power On/Standby button does not shut off system power.
Portions of the power supply and some internal circuitry remain active until AC power is removed.
CAUTION: To prevent improper cooling or thermal damage, the server PCI slots must have an expansion slot blank
or an expansion board installed.
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
• The components included with the hardware option kit
• T-10 Torx screwdriver
Before beginning installation, ensure that the server is updated with the latest operating system firmware and drivers.
Hardware options installation
112