28
2) right and left (top / bottom)
Fig. 18: Transport catch on right and left (top/bottom)
Check the hoses as well as the pneumatic system's hose connec-
tions!
Make sure that moving components can move without obstruc-
tion into the spaces they require and that the safety distances are
observed.
7.1.1 Checking for proper working order without material
The machine must only be put into operation by trained and
qualified personnel.
Before putting into operation with material, the machine must be
allowed to empty to let machine parts run in under low load. Du-
ring this period, the moving parts in particular should be checked
for excessive heat buildup and noise. An excessive buildup of
heat is an indication of incorrect alignment or use of the wrong
lubricants - this must be rectified.
Before starting up the machine for the first time, check to make
sure that:
• the machine has been installed in accordance with the regu-
lations specified,
• no foreign objects (tools, construction material etc.) have
been left in the area of the machine from the installation
process,
• moving components can move without obstruction into the
spaces they require,
• the safety distances are observed,
• the operating voltage is the same as the voltage shown on
the motor rating plate,
• the safety guards, in particular the emergency stop button
and the safety light barrier, are in proper working order.
• Remove the transport catches
1) on the operating panel
Fig. 17: Transport catch on control panel
Note
When starting the machine for the first time,
check the moving parts in particular for excessi-
ve heat buildup and noise.
An excessive buildup of heat is an indication of
incorrect alignment or use of the wrong lubri-
cants.
This must be rectified in the appropriate way.
i
7. Starting up for the first time