39
Chapter 3 Handling Information
3-1 Handling precautions
[1] The machine maintains the displayed data after the working hours are over. Thus, you
need to turn off power once or press the [CLR] key before the start of working hours.
(Unless the previous day
’
s data is cleared, the machine will not start the Plan/Advancement
calculation.)
[2] Assume a case where the clock time
is changed after the start time of working hours. If
the time is put back, the machine operates erroneously, recognizing that 24 hours or more
have elapsed. In this case, press the [CLR] key after you have put back the time.
For example, if the clock time is changed to 8:27 at 8:30, then the machine takes it for 8:27
on the next day.
[3] It is imperative that the machine be switched on before the start time of working hours. If
it is switched on after that, the machine fails to operate normally. For the machine takes it
for recovery from a power failure because it is within working hours and recognizes 24
hours or more have elapsed. In such a case, press the [CLR] key after you have switched
on the machine.
[4] Most of the causes for abnormal operation of the machine are attributed to the Working
hour setting, the Tact setting, and the above [1]/[2]/[3]. When the machine does not
operate normally, try pressing the [CLR] key after re-checking if the Working hour, Tact, and
Clock are normal. If the machine still does not return to normal condition, please contact us
because a machine trouble is suspected.
[5] When the data display is blinking, the stop function is working. See
“
2-4 Stop function
”
on
page 36.
[6] If the time is shifted, it is necessary to exchange the clock backup battery. It might be
consumed. When you have to exchange, contact the AGENT or through which you
purchased the product or our office.
[7] If you select the operation type which includes target of display when the function which
plan stop at target is selected in the function setting
(the case of setting “1”), “Plan”,
“Advancement”, “Accomplishment rate”, can’t be set any more.