15
2-1-4
.
Setting use or no use of the function which plan stop at Target.
Setting use or no use of the function which the planed quantity calculation stop when plan
reached target. It can use that choosing the type which includes target of display.
Setting
Set
value
Description
Plan
=
Not stop at target
※
0
Plan
=
Plan doesn’t stop when plan reached target.
Plan
>
Plan indication is possible.
Plan
=
stop at target
1
Plan
=
Plan stops when plan reached target.
Plan
>
Plan indication is not possible.
※
Default values
.
<How to set>
①
When on the function settings screen, press the [4] key on the keyboard.
The currently set value appears after
the sub command “C4” is displayed for 0.75 seconds.
②
As the value you want to set, input either [0] (Not used) or [1] (Used).
To set the Plan calculation stopped when the plan reached target to be used, input [1].
The resulting display is as follows:
③
Press the [ENT] key to set the change you input. If you have inadvertently input a wrong
data, press the [CLR] key and re-input the correct data.
※
When choosing the operation type which includes target of display
「
Plan
」「
Advancement
」
「
Accomplishment rate
」
can’t be set any more.
(The
case of setting “1”)
F
1
[Function settings screen]
C
4
The sub command is
displayed.
*
The set value appears.
1