24
Henrad CC FF
- Installation
29 TERMINAL WALL PLATE
This plate allows neat concealment and full compression of the
rubber seal. It should be used (where practicable):
a. When the wall is more than 24" thick (to support the flue
weight and prevent movement).
or
b. When the hole has not broken through neatly.
or
c. When the wall face is rough and the rubber seal on its own
would be ineffective.
1. Position the terminal wall plate over the terminal.
2. Drill 4 fixing holes with a 7mm (
1/4
") masonry drill.
3. Insert the 4 plastic plugs provided in flue pack B.
4. Secure the plate with 4 of the No.10 x 2" screws provided in
flue pack B.
Note.
If the terminal is less than 2m (6' 6") above ground level,
an approved terminal guard should be fitted.
Refer to 'Flue Installation', Page 7.
INSTALLATION
SIDE FLUE OUTLET