Model PFE- 591
3-17. INFORMATION MODE
Press and “6. PMP_ AIR_” shows in display.
(Continued)
Press to view the amp “DRAW” status of the pump motor
output and air valve output. “PMP ” and “AIR ” in the
display means the amps are good. A flashing “X” behind the
“PMP” or “AIR” means too much current.
Press to view the No Connect/Ground (“NC/GND”)
status of each output. This monitors a possible problem with
the relays on the output PC board.
Press to continue onto the OIL TMP reading.
7. OIL TMP
This step shows the present peanut oil temperature. The
display shows “7. OIL TMP (temp.)”.
Press to continue onto the CPU TMP reading.
8. CPU TMP
This step shows the present PC board temperature.
Press to continue onto the ANALOG reading.
9. ANALOG <1> 2.86V
This step displays the present status of any channel of the
controller’s a to d converter. This feature may be useful to a
technician troubleshooting a problem with the fryer or
controller.
The displayed value can be toggled between volts and bits
by pressing . If the displayed value has a decimal point,
it is voltage (0 to 5 VDC). If no decimal point is shown, the
value is a-to-d bits (0 - 4095).
Press and hold to exit Information Mode at any
time, or after 2 minutes, controls automatically exit
back to normal operation.
3-48
403
Summary of Contents for PFE-591
Page 1: ...Henny Penny Pressure Fryer Electric Model PFE 591 OPERATOR S MANUAL...
Page 2: ......
Page 10: ...Model PFE 591 OptionalRampUnloading 2 3 403...
Page 11: ...Model PFE 591 404 2 4...
Page 16: ......
Page 24: ...Model PFE 591 3 8 703 14 1 2 3 4 5 6 7 8 9 13 11 12 10 Figure 3 1...
Page 65: ......