Model PFE- 591
3-17. INFORMATION MODE
4. REVIEW USAGE
(Continued)
Press to view the accumulated information since the data
was manually reset:
FUNCTION
DISPLAY EX:
Day the usage data was previously reset
SINCE APR-19
Number of hours the fryer was on
PWR ON HRS 165
Number of times oil was filtered
FILTERED 34
Total number of cook cycles
TOTAL CK 462
Cook Cycles stopped before “DONE”
TUE* QUIT COOK 4
Percentage of Cook Cycles before oil change
OIL WEAR -A-
73%
Percentage of hours before oil change
OIL WEAR -B-
47%
Cook Cycles for Product #1
COOKED -1- 193
Cook Cycles for Product #2
COOKED -2- 107
Cook Cycles for Product #3
COOKED -3- 58
Cook Cycles for Product #4
COOKED -4- 0
Cook Cycles for Product #5
COOKED -5- 13
Cook Cycles for Product #6
COOKED -6- 69
Cook Cycles for Product #7
COOKED -7- 0
Cook Cycles for Product #8
COOKED -8- 7
Cook Cycles for Product #9
COOKED -9- 15
Cook Cycles for Product #0
COOKED -0- 0
Reset usage data:
Enter the Mgr Code (1, 2, 3 unless changed)
on this step to zero out all the usage
RESET USG/
information.
ENTER CODE----
Press to continue to INP A_CVHDSF_M
5. INP A_CVHDSF_M
Press to view the status of components and inputs. If the
input signal is detected, an identifying letter is displayed (see
below). If the signal is not detected, “_” is displayed.
With the COOK/PUMP switch in the COOK position, and all
inputs detected, “H_ P_ A_CVHDSF_M” shows in the display.
See below for “definition” of codes.
A = COOK/PUMP in COOK position.
B = COOK/PUMP in PUMP position
C = Solenoind continuity; won’t show with pressure on
V = Volts - 24 VAC detected
H = High Limit - If “H” is present, the high limit is good; if “H”
is missing, the high limit is tripped (overheated) or faulty
D = DRAIN SWITCH-If “D” is present, the drain handle is
closed; if “D” is missing, the drain is open or faulty
S = COOK/PUMP switch ON interlock circuit: If “S” is
present, the COOK/PUMP switch is in the COOK position.
If the “S” is missing, the COOK/PUMP is either off, failed,
or wired incorrectly
F = FAN
M = MV-Detects 24 V jumper to MV terminal
3-46
1005
Summary of Contents for PFE-591
Page 1: ...Henny Penny Pressure Fryer Electric Model PFE 591 OPERATOR S MANUAL...
Page 2: ......
Page 10: ...Model PFE 591 OptionalRampUnloading 2 3 403...
Page 11: ...Model PFE 591 404 2 4...
Page 16: ......
Page 24: ...Model PFE 591 3 8 703 14 1 2 3 4 5 6 7 8 9 13 11 12 10 Figure 3 1...
Page 65: ......