![Henny Penny PFE-591 Operator'S Manual Download Page 66](http://html1.mh-extra.com/html/henny-penny/pfe-591/pfe-591_operators-manual_2124394066.webp)
Model PFE- 591
Power switch on but fryer
completely inoperative
Pressure not exhausting at
end of Cook Cycle
Operating pressure too high
4-1. TROUBLE SHOOTING GUIDE
Problem
Cause
Correction
• Open circuit
• Solenoid or exhaust line clogged
• Deadweight clogged
•
Fryer plugged in
• Check breaker or fuse at wall
• Turn off and allow fryer to cool to
release the pressure in frypot; have
all lines, solenoid and exhaust tank
cleaned
• Turn off and allow fryer to cool to
release the pressure in frypot; clean
deadweight; See Preventive Mainte-
nance Section
DO NOT OPERATE UNIT IF PRESSURE GAUGE SHOWS HIGH PRESSURE CONDITIONS.
SEVERE INJURIES AND BURNS WILL RESULT. IMMEDIATELY PLACE THE COOK/
PUMP SWITCH IN THE OFF POSITION, WHICH RELEASES THE PRESSURE BY ALLOW-
ING THE UNIT TO COOL. DO NOT RESUME USE OF UNIT UNTIL CAUSE OF HIGH
PRESSURE HAS BEEN FOUND AND CORRECTED.
Pressure does not build
Shortening not heating
Foaming or boiling over
Shortening not draining
Filter motor won’t run
• Not enough product in frypot
• Metal shipping spacer not
removed from deadweight
• Pressure not programmed
• Lid gasket leaking
• Drain valve open
• High temperature limit tripped
• See Boil-Over chart on fryer
and beginning of Operation
Section in this manual
• Drain valve clogged
• Motor overheated
• Place full capacity product in frypot
when using fresh shortening.
• Remove shipping spacer; see
Unpacking Instructions Section
• Check programming
• Reverse or replace lid gasket
• Close drain valve.
• Reset high temperature limit; see
Operating Components Section
• Follow Boil-Over procedures from
chart
• Push cleaning rod through open
drain valve
• Reset motor; see Filter Pump Motor
Protector-Manual Reset Section
More detailed troubleshooting information is available in the Technical Manual, available at www.hennypenny.com,
or 1-800-417-8405 or 1-937-456-8405.
4-1
703
SECTION 4. TROUBLESHOOTING
Summary of Contents for PFE-591
Page 1: ...Henny Penny Pressure Fryer Electric Model PFE 591 OPERATOR S MANUAL...
Page 2: ......
Page 10: ...Model PFE 591 OptionalRampUnloading 2 3 403...
Page 11: ...Model PFE 591 404 2 4...
Page 16: ......
Page 24: ...Model PFE 591 3 8 703 14 1 2 3 4 5 6 7 8 9 13 11 12 10 Figure 3 1...
Page 65: ......