Model PFE- 591
3-17. INFORMATION MODE
Press to view the specific status of each input. An
(Continued)
underscore (“_”) indicates the input is not presently detected.
A checkmark (“ ”) indicates the signal is detecting a normal
input. A blinking (“X”) indicates the signal is presently
detected, but is detected as a half-wave (partially failed) input.
The V, H, D, S, F, P and M signals below are wired in
series. The first signal missing out of this sequence
generally causes all signals to the right of it to be
missing as well.
Press to continue onto OUTP H* P_.
6. OUTP H* P_
This mode displays the status of components and outputs. If
the output signal is detected, an identifying letter is displayed
(see below), followed by an “*”. If the output is off, “_” is
displayed.
“H” = Heat output
“P” = Pressure output
If heat is on, “H*” shows in display. If heat is off, “H_”
shows in display. If controls senses a problem with the heat
output, “H*” shows in display, with the “*” flashing.
If pressure is on, “P*” shows in display. If pressure is off,
“P_” shows in display. If controls senses a problem with the
pressure output, “P*” shows in display, with the “*” flashing.
Press to view the amp “DRAW” status of each output.
“H ” and “P ” in the display means the amps are good. A
flashing “X” behind the H or P means too much current.
Press to view the No Connect/Ground (“NC/GND”)
status of each output. This monitors a possible problem with
the relays on the output PC board.
“H ” and “P ” in the display means everything on the output
PC board is good. A flashing “X” behind the H or P means a
problem exists.
Press to view the outputs and inputs (see step 10) together.
1005
3-47
Summary of Contents for PFE-591
Page 1: ...Henny Penny Pressure Fryer Electric Model PFE 591 OPERATOR S MANUAL...
Page 2: ......
Page 10: ...Model PFE 591 OptionalRampUnloading 2 3 403...
Page 11: ...Model PFE 591 404 2 4...
Page 16: ......
Page 24: ...Model PFE 591 3 8 703 14 1 2 3 4 5 6 7 8 9 13 11 12 10 Figure 3 1...
Page 65: ......