Installation on concrete ceiling face, installation set
10
Installation of the anchor rod as per
approval ETA-12/0258:
- Drilled hole preparation
- Observe the anchoring depth and
the minimum edge distance!
- Drilled hole cleaning
- Fill drilled hole with mortar
- Slide the anchoring element into
the drilled hole
- Wait for the curing time
Legend
Anchor rod FIS A
Insert wooden spacers and
completely seal the last wooden
spacer towards the ETICS outer
surface.
(Fischer multi-adhesive and sealant)
The 5 mm spacers must not be used
as the last spacer. Then the anchor
rods can be cut to length.
Legend
Wood distances
Last wooden spacer
Sealing joint all around
The last wooden spacer must always protrude 2-5 mm from the WDSV. A
5 mm thick wooden spacer per installation set is included as a reserve.
≥ 140
≥ 55
≥ 55
1
1
2
3
Installation Instructions and Instructions for Use
28
Subject to technical modifications. – Date of Issue
September/2020
Installation on concrete ceiling face, installation set
10
Affix to stripes bitumen band on the
back of the wall bracket type I:
Affix it in a way that all holes are
completely covered.
Legend
Wall bracket type I
Bitumen band
Two wooden spacers (3) are in particular for the wall bracket type I. These
compensate the webs on the back of the bracket.
Legend
Wall bracket type I
Bitumen band
Wood distance
1
2
1
2
3
Installation Instructions and Instructions for Use
Subject to technical modifications. – Date of Issue
September/2020
29
Installation on concrete ceiling face, installation set
10
Fixing of the bracket:
Attach the wall bracket type I; while
doing so, push the anchor rod through
the bitumen band. Position washer
and nut and tighten them. The bracket
must be sealed all around again by
means of a joint between ETICS
surface and bracket (Fischer multi-
adhesive and sealant).
Legend
Wall bracket type I
Bitumen band
Sealing joint all around
The sealing joints are maintenance joints that must be checked and
maintained at regular intervals in order to prevent consequential damage.
Further installation situations, installation set 10
Constructional situation pressure-resistant
installation on concrete
With this application, the wall bracket type I must be
ordered and installed in combination with the mounting
set 2.
3
1
Installation Instructions and Instructions for Use
30
Subject to technical modifications. – Date of Issue
September/2020
Installation of the awning
Swivel the awning, as shown, into the brackets so that both noses of the
cassette or the arm bearing engages in the bracket.
Note!
Check again whether the brackets are positioned on the arm bearings. If
the arm bearing position does not coincide with the bracket position, the
static load bearing capacity is not available.
Maximum offset between arm bearing and bracket is limited by tension
pins in the brackets. The clamping part must not be clamped on the
clamping pins!
For the above mentioned swivelling in, a minimum clearance of 15 mm
between the upper side of the box and the ceiling (4) is required in the
following situation.
Legend
Bracket
Arm bearing
Minimum clearance 15
mm
Ceiling
Cassette
1
2
3
4
5