Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18
36
Adjusting Thermostat
• Press the
MENU
button to activate the menu.
• Using the
UP
and
DOWN
arrows highlight the
THERMO
icon and press
SELECT
.
• Use the
UP
and
DOWN
arrows to turn the
THERMO
ON
or
OFF
, then press
SELECT
(the
SET TEMP
will start
blinking). Using the
UP
and
DOWN
arrows select the
desired temperature and press
SELECT
.
NOTICE:
If the THERMO function is on, the SET TEMP
can be adjusted at any time by pressing the UP and DOWN
arrows.
NOTICE:
As the ROOM TEMP (RT) approaches SET
TEMP (ST), the remote system will automatically adjust
the flame height. If the RT rises above ST, the fireplace
will shut down the main burner. After this, the fireplace will
turn back on after the RT drops below the ST.
NOTICE:
The system will remember the previous TEM
-
PERATURE setting when THERMOSTAT mode is cycled
ON or OFF.
NOTICE:
If your installation includes an optional wired ON/
OFF wall switch, it should be in the OFF position when
using the RC300AU in thermostat mode
.
Adjusting Timer
• Press the
MENU
button to activate the menu.
• Using the
UP
and
DOWN
arrows highlight the
TIMER
icon and press
SELECT
.
• Use the
UP
and
DOWN
arrows to turn the
TIMER
ON
or
OFF
, then press
SELECT
. Using the
UP
and
DOWN
arrows select the desired set time and press
SELECT
.
Timer operates in increments of 15, 30, 45, 60, 90, 120
and 180 minutes.
Setting the Child Lock
• Press and hold the
MENU
and
UP
arrow buttons simul-
taneously for 4 seconds to enable or disable the child
lock feature.
NOTICE:
No functions will be usable until child lock feature
is disabled.
Power Outage
• If fireplace battery backup system IS installed at time of
power outage, fireplace operation will not be interrupted.
• If fireplace battery backup system IS NOT installed at
time of power outage, fireplace will shut off. To resume
fireplace operation, install battery backup.
NOTICE:
Battery polarity must be correct or module
damage will occur.
Manual Fireplace Shutoff
In the unlikely event that the remote wall switch malfunc
-
tions and will not turn off the fireplace, call your dealer
for service assistance. In the meantime, you may choose
one of the following actions to turn off the fireplace:
CAUTION! Risk of burns! Fireplace surfaces are hot
when operating and during cool down. Use care and wear
gloves when opening the front and accessing compo-
nents inside the fireplace.
Check remote screen for battery level indicator, replace
the batteries if low battery is indicated (See Figure 10.10).
The fireplace may be manually shut down by one of the
following methods:
Turn off the control module:
• Open or remove the decorative front to access the control
module.
• Move switch to OFF (See Figure 2.3).
Disconnect power to the control module:
• Open or remove the decorative front to access power
cord and/or back-up batteries.
• Unplug the control module and/or remove back-up
batteries.
Shut off gas to the control:
• Open or remove the decorative front and locate the gas
shut-off valve to the left of the gas control.
• Rotate the valve 90 degrees to turn off gas supply.
Turn off power to the fireplace (if back-up batteries are
not installed):
•
Locate house circuit breaker for fireplace.
• Turn off the circuit breaker.