25
Heat & Glo • SUPREME-I30-NZ • 2417-900 Rev. E • 3/18
Figure 8.7
Masonry
Factory Built
Wood Burning
Remove 18 inch x 18 inch flashing on cap by removing
3 screws. Connect both the LINK-ZC-ADPB to Class A
Pipe and the termination cap to the LINK-ZC-ADPB with
the self tapping screws provided.
OPTIONAL LINK-ZC-ADPB
FOR USE WITH CLASS A
WOODBURNING PIPE
EXHAUST
AIR
VENT PIPE
TERMINATION
CAP
LINK-DV30B
LINKSQ-DV30
Installation*
LINK-DV4-30B
LINKSQ-DV4-30
Installation**
INLET AIR
VENT PIPE
WARNING:
DO NOT BLOCK
THIS PIPE END!
INLET AIR
VENT PIPE
EXHAUST
AIR
VENT PIPE
Note: Untwist the
pipe while extend-
ing it, to achieve full
30’ length.
OR
Note
: The LINK-DV4-30B and LINKSQ-DV4-30 systems
REQUIRE this insulation.
*LINK-DV30B/LINKSQ-DV30: This installation may perform better
and allow less cold air infiltration in negative pressure settings.
**LINK-DV430B/LINKSQ-DV4-30:
• This installation may be more susceptible to cold air infiltration and
the effects of negative pressure on the appliance’s performance.
• Depending on the chimney cleanliness, consider using the
full length intake so as to lessen the possibility of sense rod
contamination and flame rectification issues.
To prevent odors and cold air drafts, it may be necessary to
place non-combustible insulation or field fabricated metal
plates around the vent pipe flues as they go through the
damper.