4 Planning and installation – HDG Hydronic
65
4.5 HDG Hydronic
I
NSTALLING
THE
CONTROL
UNIT
I
NSTALLING
THE
CONTROLLER
HOUSING
1.
Fasten the controller housing at its intended position on the wall.
For the holes to be drilled, see (1).
Danger!
Danger from electrical current or voltage!
Switch off the power supply and isolate the mains cable to the
heating system during the installation.
Caution!
Material damage due to static discharge!
Electronic components can be damaged by static discharge.
Do not touch any electronic components during the installation.
The bus cable between the HDG Pelletronic and HDG Hydronic
must be protected from inductive coupling from 230 V wires!
Only use screened cables for sensor extensions.
Figure 4/51 - Controller housing