6 Using the heating system – Structure of the menus
120
1.
Hold off with the measurement until both the threshold for the
boiler temperature (65 °C) and for the combustion chamber
temperature (550 °C) have been exceeded.
✓
The display will then show
Test allowed
.
2.
Carry out the measurement.
A
FTER
THE
MEASUREMENT
1.
After the chimney sweep test, return to the required operating
mode.
✎
See section “6.6 Changing operating mode” in this chapter.
✓
The chimney inspection is completed.
6.10 Structure of the menus
The HDG Pelletronic control unit display shows information and
parameters for the HDG Pelletmaster 15/25 boiler. All of the
information and parameters necessary to operate the equipment are
listed in the following menu structure.
In the display, depending on the configuration of the system and the
equipment installed in the heating system, some parameters may
not be shown as they are possibly not required for the particular
installation.
These will only be displayed if the corresponding hydraulic diagram
was selected during the commissioning process.
A
VAILABLE
LEVELS
The control of the heating system is divided into four levels. Each
level contains different information and parameters.
•
Information level
– Accessible for all users.
– The values displayed cannot be changed.
✎
See page 122
•
Customer level
– Accessible for all users.
– The values displayed can be changed.
✎
See page 125
If you do not change the operating mode within a certain time, the
heating system will automatically return to the previous operating
mode.