CPW 0604 BA CPW 0604 Issue 10.09.13 (From Software-Release 0.0.1.31)
45
4.5.1
Setting of the Contact Position
In this section, the procedure of setting the contact position for a welding program is
described.
The contact position is not assigned to a program!
The contact position must be re-determined after each change
of equipment and/or change of program!
The contact signal must always be calibrated for the shortest
stud!
Subsequent options are selected depending on available
machine configurations!
Selection of option Ux:
U1 = welding head 1 / Z axis U1
U2 = welding head 2 / Z axis U2
U3 = welding head 3 / Z axis U3
U4 = welding head 4 / Z axis U4
Selection of option Bx:
B0 = without option
B1 = downholder
B2 = spray
B3 = downholder and spray
4 Function
4.5 Menu MANUAL / CONTACT