CPW 0604 BA CPW 0604 Issue 10.09.13 (From Software-Release 0.0.1.31)
35
4.4.1
Description of Operating Elements
Key switch position „Start with key“
Close door and program start with START push button
Key switch position „Start with door“
Program starts automatically with closure of door
Change „Clamp open / Clamp closed“
must be fulfilled!
Start automatic run
Start after STOP
Start after program instruction M00 (programmable stop)
Stop for automatic run
Push button Clamp
Manual opening and closing of the earth clamp
Push button INIT / RESET (Error confirmation)
Confirmation of one or more mistakes after remedy.
Start after error in automatic run
Touch key „LINE =“ and push button „START“
Starts automatic run of the actual program line!
Stud must be removed from the chuck in advance!
Start after error in automatic run
Touch key „LINE >>“ and push button „START“
starts automatic run in the next program line!
Stud must be removed from the chuck in advance!
4 Function
4.4 Menu AUTOMATIC