77
DSE
INDUSTRIAL ETHERNET
Explanation
No.
Byte
Format
R/W
Type
Module
Filler
extended
Mean value
RO
F32
2
Mean value of filling results.
Standard
deviation
RO
F32
2
Standard deviation of filling
results.
Total weight
RO
F32
2
Total weight of filling results.
Current
dosing time
RO
U16
2
Current filling time.
Current
coarse flow
time
RO
U16
2
Current coarse flow filling time.
Current fine
flow time
RO
U16
2
Current fine flow filling time.
Filler
control
Target
weight
RW
F32
2
Target weight.
Fine flow
pre-act
RW
F32
2
Fine flow pre-act, see also
Fig. 7.18, page 67.
Coarse flow
pre-act
RW
F32
2
Coarse flow pre-act, see also
Fig. 7.18, page 67.
Check
weigher
process
data
Check
weigher
result
RO
F32
4
Weighing result
Check
weigher
result status
RO
U16
2
Weighing result status
Bit 0: 1 = Net
Bit 1: 1 = PT (Preset tare)
Check
weigher
result count
RO
U32
4
Number of weighing results
Check
weigher
status
(output
flags)
RO
U16
2
Bit 0: New trigger result (toggles)
Bit 1: Settling time active
Bit 2: Measuring time active
Check
weigher
commands
(input flags)
WO
U16
2
Bit 0: Trigger (light barrier)
Bit 1: Clear trigger statistic
Summary of Contents for DSE
Page 1: ...DSE ENGLISH DEUTSCH Operating Manual Bedienungsanleitung ...
Page 3: ...DSE ENGLISH DEUTSCH Operating Manual ...
Page 22: ...DSE INSTALLATION 20 Fig 5 7 DSE in star topology left and ring topology right ...
Page 41: ...39 DSE CONNECTINGDSE VIA TCP IP Fig 6 24 DSE signals ...
Page 102: ...DSE ENGLISH DEUTSCH Bedienungsanleitung ...
Page 122: ...21 DSE INSTALLATION Abb 5 7 DSE in Sterntopologie links und Ringtopologie rechts ...
Page 203: ...DSE ENTSORGUNG 102 ...
Page 204: ...HBK Hottinger Brüel Kjaer www hbkworld com info hbkworld com A05529 01 X00 02 ...