![HBK DSE Operating Manual Download Page 178](http://html1.mh-extra.com/html/hbk/dse/dse_operating-manual_2111691178.webp)
77
DSE
INDUSTRIAL ETHERNET
Erläuterung
Anz.
Byte
Format
R/W
Typ
Modul
Filler
process
data
Filling result
RO
F32
4
Füllergebnis.
Filling result
status
RO
U16
2
Status Füllergebnis.
Filling count
RO
U32
4
Anzahl Füllergebnisse.
Commands
(Input flags
filler)
RW
U16
2
Bit 0: Start filling
Bit 1: Abort filling
Bit 2: Clear results
Filling
process
status
RO
U16
2
IDLE: 0
START_DELAY: 1
START_WEIGHT: 2
TARE: 3
FIRST_FINE_LOCKOUT: 4
FIRST_FINE_FLOW: 5
COARSE_FLOW_LOCKOUT: 6
COARSE_FLOW: 7
FINE_FLOW_LOCKOUT: 8
FINE_FLOW: 9
RESIDUAL_FLOW: 10
TOLERANCE_CONTROL: 11
REFILLING: 12
READY: 13
EMPTYING: 14
Valve status
RO
U16
2
Bit 0: Coarse flow
Bit 1: Fine flow
Alarm
RO
U16
2
NONE: 0
START_WEIGHT_TOO_LOW: 1
START_WEIGHT_TOO_HIGH: 2
MAX_FILLING_TIME: 3
TOLERANCE_LOWER: 4
TOLERANCE_UPPER: 5
MANUALLY_STOPPED: 6
OVFL: 7
Summary of Contents for DSE
Page 1: ...DSE ENGLISH DEUTSCH Operating Manual Bedienungsanleitung ...
Page 3: ...DSE ENGLISH DEUTSCH Operating Manual ...
Page 22: ...DSE INSTALLATION 20 Fig 5 7 DSE in star topology left and ring topology right ...
Page 41: ...39 DSE CONNECTINGDSE VIA TCP IP Fig 6 24 DSE signals ...
Page 102: ...DSE ENGLISH DEUTSCH Bedienungsanleitung ...
Page 122: ...21 DSE INSTALLATION Abb 5 7 DSE in Sterntopologie links und Ringtopologie rechts ...
Page 203: ...DSE ENTSORGUNG 102 ...
Page 204: ...HBK Hottinger Brüel Kjaer www hbkworld com info hbkworld com A05529 01 X00 02 ...