3. Clean contacts with a small wire brush (P/N 321-0000-477).
4. Spray the contacts again with the deoxidizing agent. This will rinse out debris.
5. Remove all residue of deoxidizing agent from the connection. Not removing deoxidizing agent can damage
the connector seal.
6. Dry out the connection with dry, compressed air. Dust Off Electronics Duster (P/N 222-4001-007) is
recommended however, if unavailable, alternate compressed air sources can be used. If using compressed air
from a large volume air compressor, be sure the lines are free of moisture.