C
HAPTER
5
32
Hawkeye® Installation Manual for RoGator C-Series RG900, RG1100, RG1300
FIGURE 5. Access to Electrical Box for Hawkeye Chassis Cable
MOUNTING PLATE PREPARATION AND ECU INSTALLATION
1. Using the Product Controller II ECU as a template, mark the mounting plate for the new ECU mounting post
pattern. It may be possible to use some existing holes in the plate.
NOTE:
Mount the Product Controller II ECU to the side of the plate facing toward the rear of the machine
with the cable connectors pointing toward the bottom of the electrical box. Position the ECU parallel
with the top edge of the mounting plate. Keep in mind the electrical box cover when positioning and
marking the plate for mounting the Product Controller II ECU.
2. Use a 5/16” drill bit to make any holes in the mounting plate.
3. Use the supplied 1/4” bolts, hex nuts, and flat washers to mount the Product Controller II ECU to the mounting
plate facing toward the rear of the machine.
IN CAB CONNECTIONS
VIPER 4 ISOBUS CONNECTION
1. Connect the two 2-pin Deutsch ISOBUS connectors located behind the Viper
®
4 together.
FIGURE 6. ISOBUS Connections
Drill 1-1/2” Hole
Summary of Contents for RG1300
Page 8: ...CHAPTER 1 4 Hawkeye Installation Manual for RoGator C Series RG900 RG1100 RG1300...
Page 20: ...CHAPTER 2 16 Hawkeye Installation Manual for RoGator C Series RG900 RG1100 RG1300...
Page 22: ...CHAPTER 3 18 Hawkeye Installation Manual for RoGator C Series RG900 RG1100 RG1300...
Page 32: ...CHAPTER 4 28 Hawkeye Installation Manual for RoGator C Series RG900 RG1100 RG1300...
Page 38: ...CHAPTER 5 34 Hawkeye Installation Manual for RoGator C Series RG900 RG1100 RG1300...
Page 43: ...016 0171 655 Rev E 39 CHASSIS CABLE INSTALLATION SYSTEM DIAGRAMS...
Page 50: ...APPENDIX A 46 Hawkeye Installation Manual for RoGator C Series RG900 RG1100 RG1300...
Page 54: ...APPENDIX B 50 Hawkeye Installation Manual for RoGator C Series RG900 RG1100 RG1300...
Page 58: ...Index 54 Hawkeye Installation Manual for RoGator C Series RG900 RG1100 RG1300...