6
OPERATION
114
Senator S24S
01/2019 - Senator S24S Radar Manual v1.00 en
F
F
F
F
Configuration
Configuration
Configuration
Configuration
Inconsistent NVRAM
Incorrect data in the parameter
memory.
De-energize and then energize the
device again.
If the message is shown again, tell
the supplier.
Incons. Converter Calib.
Incorrect calibration data in the
converter module.
Tell the supplier.
Incons. Sensor Calibration
Incorrect calibration data in the
sensor module.
NVRAMs Mismatch
The serial number of the display
screen does not agree with the
serial number of the electronics
module.
Make sure that the display screen
agrees with the electronic module.
Go to Full Setup
Full Setup
Full Setup
Full Setup > Device
Device
Device
Device >
Information
Information
Information
Information and record the data in
menu items C7.1.5 Electronic
C7.1.5 Electronic
C7.1.5 Electronic
C7.1.5 Electronic
Revision
Revision
Revision
Revision and C7.1.6 Software
C7.1.6 Software
C7.1.6 Software
C7.1.6 Software
Revision
Revision
Revision
Revision. If it is necessary, tell the
supplier.
Conv. NVRAM Layout Error
Incorrect data in the parameter
memory.
De-energize and then energize the
device again.
If the message is shown again, tell
the supplier.
Disp. NVRAM Layout Error
Incorrect data after an update of
the firmware.
CO Float Error
2
The device cannot use the
measurement data because the
device settings are incorrect.
You must make the device go back
to its factory settings. Enter
Program mode. Set the device to
the "Expert" access level. Go to
Full Setup
Full Setup
Full Setup
Full Setup > Device
Device
Device
Device > Factory
Factory
Factory
Factory
Default
Default
Default
Default > Reset to Factory
Reset to Factory
Reset to Factory
Reset to Factory
Default?
Default?
Default?
Default? and set this menu item to
"Yes". Then go back to Normal
mode and set the "Save
Configuration?" page to "Yes". De-
energize and then energize the
device again.
If the message is shown again, tell
the supplier.
C
C
C
C
Electronics
Electronics
Electronics
Electronics
FW Update
A firmware update of the
converter module continues.
Wait for the firmware update to
finish.
Status
type
Error message
Description
Corrective action