HAULOTTE GROUP
4 EQUIPMENT MAINTENANCE
66
TABLE 4-3 ERROR CODE DEFINITIONS
ERROR MESSAGE
ERROR DEFINITION
TO SIMULATE ERROR
TO CLEAR ERROR
COMMENTS
143 OPEN CIRCUIT
(FWS C32)
A load of less than 70mA
was detected when
(FWS C32) circuit was
energized
Disconnect a wire from
(FWS C32) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
144 SHORTED CIRCUIT
(FWS C32)
Excessive load was
detected when (FWS
C32) circuit was
energized
Use a piece of wire to
short the (FWS C32) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
145 OPEN CIRCUIT
(FWS C33)
A load of less than 70mA
was detected when
(FWS C33) circuit was
energized
Disconnect a wire from
(FWS C33) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
146 SHORTED CIRCUIT
(FWS C33)
Excessive load was
detected when (FWS
C33) circuit was
energized
Use a piece of wire to
short the (FWS C33) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
147 OPEN CIRCUIT
(FWS C34)
A load of less than 70mA
was detected when
(FWS C34) circuit was
energized
Disconnect a wire from
(FWS C34) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
148 SHORTED CIRCUIT
(FWS C34)
Excessive load was
detected when (FWS
C34) circuit was
energized
Use a piece of wire to
short the (FWS C34) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
149 OPEN CIRCUIT
(FWS R2)
A load of less than 70mA
was detected when
(FWS R2) circuit was
energized
Disconnect a wire from
(FWS R2) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
150 SHORTED CIRCUIT
(FWS R2)
Excessive load was
detected when (FWS R2)
circuit was energized
Use a piece of wire to
short the (FWS R2) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
151 OPEN CIRCUIT
(FWS GEN G1)
A load of less than 70mA
was detected when
(FWS Gen G1) circuit
was energized
Disconnect a wire from
(FWS Gen G1) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
152 SHORTED CIRCUIT
(FWS GEN G1)
Excessive load was
detected when (FWS
Gen G1) circuit was
energized
Use a piece of wire to
short the (FWS Gen G1)
coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
153 OPEN CIRCUIT
(FWS CON 24V)
A load of less than 70mA
was detected when
(FWS Con 24V) circuit
was energized
Disconnect a wire from
(FWS Con 24V) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
154 SHORTED CIRCUIT
(FWS CON 24V)
Excessive load was
detected when (FWS
Con 24V) circuit was
energized
Use a piece of wire to
short the (FWS Con 24V)
coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
155 OPEN CIRCUIT
(FWS SPARE 1)
A load of less than 70mA
was detected when
(FWS Spare 1) circuit
was energized
Disconnect a wire from
(FWS Spare 1) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
156 SHORTED CIRCUIT
(FWS SPARE 1)
Excessive load was
detected when (FWS
Spare 1) circuit was
energized
Use a piece of wire to
short the (FWS Spare 1)
coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
157 OPEN CIRCUIT
(FWS SPARE 2)
A load of less than 70mA
was detected when
(FWS Spare 2) circuit
was energized
Disconnect a wire from
(FWS Spare 2) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
Summary of Contents for xlb-4725a
Page 1: ...OPERATOR S MAINTENANCE MANUAL B33 01 0104 Rev 4 August 2012...
Page 70: ...HAULOTTE GROUP 5 CYLINDER REPLACEMENT 70...
Page 78: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 78 DECAL KIT ANSI...
Page 80: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 80 IDENTIFICATION PLATES OPTIONAL EQUIPMENT ANSI...
Page 86: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 86...
Page 92: ...HAULOTTE GROUP 7 OPTIONAL EQUIPMENT 92...
Page 98: ...HAULOTTE GROUP 8 MATERIAL SAFETY 98 MATERIAL SAFETY DATA SHEET POWERFLOW AW HVI HYDRAULIC OIL...
Page 116: ...HAULOTTE GROUP 9 ANSI REPRINT 116...