TABLE 4-3 ERROR CODE DEFINITIONS
ERROR MESSAGE
ERROR DEFINITION
TO SIMULATE ERROR
TO CLEAR ERROR
COMMENTS
073 OPEN CIRCUIT
SPARE OUTPUT
A load of less than 70mA
was detected when
Spare Output circuit was
energized
Disconnect a wire from
Spare Output coil
This is a latched error.
Power must be cycled to
clear error
Not Used
074 SHORTED CIRCUIT
SPARE OUTPUT
Excessive load was
detected when Spare
Output circuit was
energized
Use a piece of wire to
short the Spare Output
coil
This is a latched error.
Power must be cycled to
clear error
Not Used
075 OPEN CIRCUIT
AC SWITCH
A load of less than 70mA
was detected when AC
Switch circuit was
energized
Disconnect a wire from
AC Switch coil
Error Suppressed due to
low current draw
076 SHORTED CIRCUIT
AC SWITCH
Excessive load was
detected when AC
Switch circuit was
energized
Use a piece of wire to
short the AC Switch coil
Error Suppressed due to
low current draw
077 OPEN CIRCUIT
STROBE
A load of less than 70mA
was detected when
Strobe circuit was
energized
Disconnect a wire from
Strobe
Error Suppressed due to
low current draw
078 SHORTED CIRCUIT
STROBE
Excessive load was
detected when Strobe
circuit was energized
Use a piece of wire to
short the Strobe coil
Error Suppressed due to
low current draw
079 OPEN CIRCUIT
DRIVE PWM
A load of less than 70mA
was detected when Drive
PWM circuit was
energized
Disconnect a wire from
Drive PWM coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with Drive
option only
080 SHORTED CIRCUIT
DRIVE PWM
Excessive load was
detected when Drive
PWM circuit was
energized
Use a piece of wire to
short the Drive PWM coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with Drive
option only
081 OPEN CIRCUIT
DRIVE ENABLE
A load of less than 70mA
was detected when Drive
Enable circuit was
energized
Disconnect a wire from
Drive Enable coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with Drive
option only
082 SHORTED CIRCUIT
DRIVE ENABLE
Excessive load was
detected when Drive
Enable circuit was
energized
Use a piece of wire to
short the Drive Enable
coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with Drive
option only
083 OPEN CIRCUIT
DRIVE DUMP (C21)
A load of less than 70mA
was detected when Drive
Dump (C21) circuit was
energized
Disconnect a wire from
Drive Dump (C21) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WD
option only
084 SHORTED CIRCUIT
DRIVE DUMP (C21)
Excessive load was
detected when Drive
Dump (C21) circuit was
energized
Use a piece of wire to
short the Drive Engage
coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WD
option only
085 OPEN CIRCUIT
TURN LEFT (C22)
A load of less than 70mA
was detected when Turn
Left (C22) circuit was
energized
Disconnect a wire from
Turn Left (C22) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WD
option only
086 SHORTED CIRCUIT
TURN LEFT (C22)
Excessive load was
detected when Turn Left
(C22) circuit was
energized
Use a piece of wire to
short the Turn Left (C22)
coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WD
option only
087 OPEN CIRCUIT
TURN RIGHT (C23)
A load of less than 70mA
was detected when Turn
Right (C23) circuit was
energized
Disconnect a wire from
Turn Right (C23) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WD
option only
Summary of Contents for xlb-4725a
Page 1: ...OPERATOR S MAINTENANCE MANUAL B33 01 0104 Rev 4 August 2012...
Page 70: ...HAULOTTE GROUP 5 CYLINDER REPLACEMENT 70...
Page 78: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 78 DECAL KIT ANSI...
Page 80: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 80 IDENTIFICATION PLATES OPTIONAL EQUIPMENT ANSI...
Page 86: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 86...
Page 92: ...HAULOTTE GROUP 7 OPTIONAL EQUIPMENT 92...
Page 98: ...HAULOTTE GROUP 8 MATERIAL SAFETY 98 MATERIAL SAFETY DATA SHEET POWERFLOW AW HVI HYDRAULIC OIL...
Page 116: ...HAULOTTE GROUP 9 ANSI REPRINT 116...