TABLE 4-3 ERROR CODE DEFINITIONS
ERROR MESSAGE
ERROR DEFINITION
TO SIMULATE ERROR
TO CLEAR ERROR
COMMENTS
128 SHORTED CIRCUIT
FS RET (FWS C24)
Excessive load was
detected when FS Ret
(FWS C24) circuit was
energized
Use a piece of wire to
short the FS Ret (FWS
C24) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
129 OPEN CIRCUIT
FS EXT (FWS C25)
A load of less than 70mA
was detected when FS
Ext (FWS C25) circuit
was energized
Disconnect a wire from
FS Ext (FWS C25) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
130 SHORTED CIRCUIT
FS RET (FWS C25)
Excessive load was
detected when FS Ext
(FWS C25) circuit was
energized
Use a piece of wire to
short the FS Ext (FWS
C25) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
131 OPEN CIRCUIT
DC D FWD (FWS
C26)
A load of less than 70mA
was detected when DC D
Fwd (FWS C26) circuit
was energized
Disconnect a wire from
DC D Fwd (FWS C26)
coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
132 SHORTED CIRCUIT
DC D FWD (FWS
C26)
Excessive load was
detected when DC D
Fwd (FWS C26) circuit
was energized
Use a piece of wire to
short the DC D Fwd
(FWS C26) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
133 OPEN CIRCUIT
DC D REV (FWS
C27)
A load of less than 70mA
was detected when DC D
Rev (FWS C27) circuit
was energized
Disconnect a wire from
DC D Rev (FWS C27)
coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
134 SHORTED CIRCUIT
DC D REV (FWS
C27)
Excessive load was
detected when DC D Rev
(FWS C27) circuit was
energized
Use a piece of wire to
short the DC D Rev
(FWS C27) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
135 OPEN CIRCUIT
DC D (FWS C28)
A load of less than 70mA
was detected when DC D
(FWS C28) circuit was
energized
Disconnect a wire from
DC D (FWS C28) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
136 SHORTED CIRCUIT
DC D (FWS C28)
Excessive load was
detected when DC D
(FWS C28) circuit was
energized
Use a piece of wire to
short the DC D (FWS
C28) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
137 OPEN CIRCUIT
DC D (FWS C29)
A load of less than 70mA
was detected when DC D
(FWS C29) circuit was
energized
Disconnect a wire from
DC D (FWS C29) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
138 SHORTED CIRCUIT
DC D (FWS C29)
Excessive load was
detected when DC D
(FWS C29) circuit was
energized
Use a piece of wire to
short the DC D (FWS
C29) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
139 OPEN CIRCUIT
DC D (FWS C30)
A load of less than 70mA
was detected when DC D
(FWS C30) circuit was
energized
Disconnect a wire from
DC D (FWS C30) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
140 SHORTED CIRCUIT
DC D (FWS C30)
Excessive load was
detected when DC D
(FWS C30) circuit was
energized
Use a piece of wire to
short the DC D (FWS
C30) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
141 OPEN CIRCUIT
DC D (FWS C31)
A load of less than 70mA
was detected when DC D
(FWS C31) circuit was
energized
Disconnect a wire from
DC D (FWS C31) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at |
power up
Machines with 4WS
option only
142 SHORTED CIRCUIT
DC D (FWS C31)
Excessive load was
detected when DC D
(FWS C31) circuit was
energized
Use a piece of wire to
short the DC D (FWS
C31) coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Machines with 4WS
option only
Summary of Contents for xlb-4725a
Page 1: ...OPERATOR S MAINTENANCE MANUAL B33 01 0104 Rev 4 August 2012...
Page 70: ...HAULOTTE GROUP 5 CYLINDER REPLACEMENT 70...
Page 78: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 78 DECAL KIT ANSI...
Page 80: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 80 IDENTIFICATION PLATES OPTIONAL EQUIPMENT ANSI...
Page 86: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 86...
Page 92: ...HAULOTTE GROUP 7 OPTIONAL EQUIPMENT 92...
Page 98: ...HAULOTTE GROUP 8 MATERIAL SAFETY 98 MATERIAL SAFETY DATA SHEET POWERFLOW AW HVI HYDRAULIC OIL...