HAULOTTE GROUP
4 EQUIPMENT MAINTENANCE
50
CLEVIS PIN
PIN
PLATFORM
GROUND
PLATFORM
MOUNTING
BRACKET
OVERLOAD PROTECTION CALIBRATION PROCEDURE
Load Sense Zeroing
1) Remove
the
CLEVIS PIN
securing the
PLATFORM
to the
PLATFORM MOUNTING BRACKET
, allowing
the
PLATFORM
to pivot about the
PLATFORM PIN
and rest on the ground. This removes the load
from the
LOAD CELL
.
Refer to Figure 4-13.
Figure 4-13. Platform Position
2) Use the ground (lower) control panel to access the control box maintenance menu.
Refer to Figure 4-14
Figure 4-14. Ground (Lower) Control Panel for Overload Protection
3) Verify that the
KEY SWITCH
(1)
is turned to the
GROUND
(1A)
icon, and that both
EMERGENCY STOP
(2)
buttons (ground and platform) are “pulled out”
4) Enter the maintenance mode by pressing (pushing) both
ROTATE
(5)
buttons and the
OUTRIGGER
EXTEND
(6)
button on the ground (lower) control panel simultaneously and holding for 5 seconds.
4A
9A
7
9B
8
4B
6
5
5
3
1A
2
1A
Summary of Contents for xlb-4725a
Page 1: ...OPERATOR S MAINTENANCE MANUAL B33 01 0104 Rev 4 August 2012...
Page 70: ...HAULOTTE GROUP 5 CYLINDER REPLACEMENT 70...
Page 78: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 78 DECAL KIT ANSI...
Page 80: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 80 IDENTIFICATION PLATES OPTIONAL EQUIPMENT ANSI...
Page 86: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 86...
Page 92: ...HAULOTTE GROUP 7 OPTIONAL EQUIPMENT 92...
Page 98: ...HAULOTTE GROUP 8 MATERIAL SAFETY 98 MATERIAL SAFETY DATA SHEET POWERFLOW AW HVI HYDRAULIC OIL...
Page 116: ...HAULOTTE GROUP 9 ANSI REPRINT 116...