HAULOTTE GROUP
4 EQUIPMENT MAINTENANCE
59
TABLE 4-3 ERROR CODE DEFINITIONS
ERROR MESSAGE
ERROR DEFINITION
TO SIMULATE ERROR
TO CLEAR ERROR
COMMENTS
027 OPEN CIRCUIT
SECONDARY
DOWN
A load of less than 70mA
was detected when
Secondary Down circuit
was energized
Disconnect a wire from
Secondary Down coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Articulating Boom Models
028 SHORTED CIRCUIT
SECONDARY
DOWN
Excessive load was
detected when
Secondary Down circuit
was energized
Use a piece of wire to
short the Secondary
Down coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Articulating Boom Models
029 OPEN CIRCUIT
JIB UP
A load of less than 70mA
was detected when Jib
Up circuit was energized
Disconnect a wire from
Jib Up coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Articulating Boom Models
030 SHORTED CIRCUIT
JIB UP
Excessive load was
detected when Jib Up
circuit was energized
Use a piece of wire to
short the Jib Up coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Articulating Boom Models
031 OPEN CIRCUIT
JIB DOWN
A load of less than 70mA
was detected when Jib
Down circuit was
energized
Disconnect a wire from
Jib Down coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Articulating Boom Models
032 SHORTED CIRCUIT
JIB DOWN
Excessive load was
detected when Jib Down
circuit was energized
Use a piece of wire to
short the Jib Down coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Articulating Boom Models
033 OPEN CIRCUIT
EXTEND
A load of less than 70mA
was detected when
Extend circuit was
energized
Disconnect a wire from
Extend coil
This is a latched error.
Power must be cycled to
clear error
Checked only at power up
034 SHORTED CIRCUIT
EXTEND
Excessive load was
detected when Extend
circuit was energized
Use a piece of wire to
short the Extend coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
035 OPEN CIRCUIT
RETRACT
A load of less than 70mA
was detected when
Retract circuit was
energized
Disconnect a wire from
Retract coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
036 SHORTED CIRCUIT
RETRACT
Excessive load was
detected when Retract
circuit was energized
Use a piece of wire to
short the Retract coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
037 OPEN CIRCUIT
PLATFORM LEVEL
UP
A load of less than 70mA
was detected when
Platform Level Up circuit
was energized
Disconnect a wire from
Platform Level Up coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
038 SHORTED CIRCUIT
PLATFORM LEVEL
UP
Excessive load was
detected when Platform
Level Up circuit was
energized
Use a piece of wire to
short the Platform Level
Up coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
039 OPEN CIRCUIT
PLATFORM LEVEL
DOWN
A load of less than 70mA
was detected when
Platform Level Down
circuit was energized
Disconnect a wire from
Platform Level Down coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
040 SHORTED CIRCUIT
PLATFORM LEVEL
DOWN
Excessive load was
detected when Platform
Level Down circuit was
energized
Use a piece of wire to
short the Platform Level
Down coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
041 OPEN CIRCUIT
PLATFORM CW
A load of less than 70mA
was detected when
Platform CW circuit was
energized
Disconnect a wire from
Platform CW coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Articulating Boom Models
042 SHORTED CIRCUIT
PLATFORM CW
Excessive load was
detected when Platform
CW circuit was energized
Use a piece of wire to
short the Platform CW
coil
This is a latched error.
Power must be cycled to
clear error
Checked only at
power up
Articulating Boom Models
Summary of Contents for xlb-4725a
Page 1: ...OPERATOR S MAINTENANCE MANUAL B33 01 0104 Rev 4 August 2012...
Page 70: ...HAULOTTE GROUP 5 CYLINDER REPLACEMENT 70...
Page 78: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 78 DECAL KIT ANSI...
Page 80: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 80 IDENTIFICATION PLATES OPTIONAL EQUIPMENT ANSI...
Page 86: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 86...
Page 92: ...HAULOTTE GROUP 7 OPTIONAL EQUIPMENT 92...
Page 98: ...HAULOTTE GROUP 8 MATERIAL SAFETY 98 MATERIAL SAFETY DATA SHEET POWERFLOW AW HVI HYDRAULIC OIL...