HAULOTTE GROUP
1 SAFETY
9
DURING OPERATION
Ensure the following general safety precautions are followed while operating the aerial work platform:
ALWAYS
position away from power lines, this ensures that no part of the aerial work platform
accidentally reaches into an unsafe area. This includes full extension of the telescoping boom
through 700º of Non-Continuous rotation.
ALWAYS
check with local electrical authorities regarding any local requirements which may differ
from those shown in Table 1-1.
ALWAYS
keep away from an aerial work platform that is exposed to electrically charged power lines.
If the aerial work platform comes in contact with electrically charged power lines,
NEVER
touch or
operate the aerial work platform until power lines are shut off.
ALWAYS
operate only on a firm and level surface.
NEVER
operate on surfaces that do not support
the aerial work platform with its rated load capacity, or on surfaces that do not support force exerted
by the outriggers during aerial work platform operation. Operate only on surfaces that can support a
pressure of 25 psi (1.8 kg/cm
2
) to ensure safe operation.
ALWAYS
keep personnel away from potential pinch and shear points and from potential crush
hazards as indicated by decals attached to the aerial work platform.
ALWAYS
keep the safety bar lowered (closed) unless personnel are entering or exiting the work
platform.
DANGER
This aerial work platform is NOT insulated for use near
electrical power lines and DOES NOT provide protection
from contact with or close proximity to any electrically
charged conductor. Operator must maintain safe
clearances at all times (10 ft (3.05m) minimum) and must
always allow for Platform movement due to gusty winds.
Always contact power company before working near
power lines. Assume every power line is live. Power lines
can be blown by the wind.
Refer to Table 1-1 for minimum safe approach distances
between the machine and electrical power lines.
TABLE 1-1. MINIMUM SAFE APPROACH DISTANCES
Minimum Safe Approach
Distance
Voltage Range
(Phase to Phase)
(Feet) (Meters)
0 to 300V
Avoid Contact
Over 300V to 50KV
10
3.05
Over 50KV to 200KV
15
4.60
Over 200KV to 350KV
20
6.10
Over 350KV to 500KV
25
7.62
Over 500KV to 750KV
35
10.67
Over 750KV to 1000KV
45
13.72
Summary of Contents for 3522A
Page 1: ...OPERATOR S MAINTENANCE MANUAL B33 01 0093 Rev 4 May 2013...
Page 76: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 76 DECAL KIT ANSI...
Page 78: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 78 IDENTIFICATION PLATES OPTIONAL EQUIPMENT ANSI...
Page 84: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 84 DECAL KIT CE...
Page 86: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 86 IDENTIFICATION PLATES OPTIONAL EQUIPMENT CE...
Page 88: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 88 DECAL KIT AU...
Page 90: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 90 IDENTIFICATION PLATES OPTIONAL EQUIPMENT AU...
Page 92: ...HAULOTTE GROUP 6 DECAL REPLACEMENT 92...
Page 106: ...HAULOTTE GROUP 8 MATERIAL SAFETY 106 MATERIAL SAFETY DATA SHEET POWERFLOW AW HVI HYDRAULIC OIL...