Bedienungsanleitung H1280
HASCO hot runner 27
Mean output level
The mean output level is the average output level that has been
output over a specified period of time.
Internal setpoint value
The internal setpoint value is the setpoint value currently employed
for control. Depending on the operating conditions and functions, the
internal setpoint value may deviate from the actual setpoint value. In
standby mode, for example, the controller applies the set standby
temperature. In this example, the internal setpoint value would
display the standby temperature.
The following examples illustrate the different presentations:
Presentation
Meaning
Zone 1
Actual [°C]
OFF
Setpoint [°C]
Zone 3 is inactive, the outputs are deactivated.
The display boxes for the process values remain greyed out.
Zone 1
Actual [°C]
235
Setpoint [°C]
238
Active zone with the actual and setpoint value display
Zone 1
Actual [°C]
235
Setpoint [°C]
238
Y [%]
15%
I [A]
8.5
Active zone with 4 process values:
- actual value
- setpoint value
- output level
- heating current
Zone 1
Actual [°C]
240
Setpoint [°C]
230
T [°C]
20
-20
Active zone with actual and setpoint value and graphic display of
the control deviation
T.
If the bar display for the control deviation is above the zero line,
the actual value is too high. In this example, the actual value is
10° above the setpoint value.
The display range of the bar corresponds to the tolerance range
value, in this case 20°.
Zone 1
Active zone with graphic display of the control deviation.
If the bar display of the control deviation is below the zero line,
the actual value is too low.