![Hasco H1280 Series Operating Instructions Manual Download Page 13](http://html1.mh-extra.com/html/hasco/h1280-series/h1280-series_operating-instructions-manual_2105904013.webp)
14 HASCO hot runner
It indicates that the current user level has
been released.
Timer
This symbol is only visible if the timer is
activated and the device is switched on or off
at the pre-programmed time.
xxxx.rzp
Recipe file
Name of the last recipe loaded. If values have
been added after activation of the recipe, an *
is added to the name.
5.2 Selection of zones and groups for operation
The page for the operation of zones is divided in two. The left side of the screen always shows the zone or zone groups
that are to be operated. The actual input is then made on the right side.
Figure 8 -
Sample page for entering setpoint values
Before zones are operated, they must first be selected. This is done by clicking on the desired zone. A selected zone
has a white surround. A selected zone can be deselected by clicking on it again (toggle function). Rapid selection of a
number of zones can be performed by running a finger over them in one go.
Zones can be allocated to a freely named group. Zones that belong to a group display their group colour under the zone
name. To select an entire group of zones, click on the respective group button (above the zone display). To
select/deselect all the zones, click on the “All” button. Operation of the zones is performed on the right side.
5.3 Navigation menu
For a better overview, the navigation menu has been divided into three levels.
Setup
For setting and configuring the mould-specific settings for all the control zones.
Operation
For displaying and modifying values and displaying faults during operation.
Settings
For the general configuration and readout of information about the controller.
Each of these three main areas is, in turn, divided into subareas that are explained in more detail below.
Setpoint value
Standby temperature
Boost
Boost duration
Groups
Operating mode
Setpoint values
Finish
All
None
Group 1
Group 2
1. Select zones and parameters
2. Enter value, repeat if necessary
then continue with Finish
Selection
Setup > Quick start > Setpoint values
20.02.2019 12:30:42