Harvia KM60SE Instructions For Installation And Use Manual Download Page 23

EN

DE

23

3. INSTRUCTIONS FOR INSTALLATION

3. MONTAGEANLEITUNG

3.1. Before Installation

Before installing the heater, study the instructions 

for installation. Check the following points:

• 

Is the output and type of the heater suitable for 

the sauna room? 

The cubic volumes given in 

table 2 should be followed.

• 

Is the supply voltage suitable for the heater?

• 

The location of the heater fulfils the minimum 

requirements concerning safety distances given 

in fig. 5 and table 2.

Note! Only one electrical heater may be installed in 

the sauna room. The heater should be installed so 

that the warning texts can also be read without dif-

ficulty after the installation.

Heater must not be mounted in a recess!

 

 

3.2. Fastening the Heater on a Wall

1.  Fasten the wall-mounting rack on the wall by us-

ing the screws which come with the rack. Observe 

the minimum safety distances given in table 2 

and fig. 5 and 6.

NOTE! There must be a support, e.g. a board, be-

hind the panel, so that the fastening screws can be 

screwed into a thicker wooden material than the 

panel. If there are no boards behind the panel, the 

boards can also be fastened on the panel.

2.  Lift the heater to the rack on the wall so that the 

fastening hooks of the lower part of the rack go 

behind the edge of the heater body.

3.  Fasten the upper part of the heater to the wall-

mounting rack by using the fastening clamp.

 

 

3.3. Safety Railing

If a safety railing is built around the heater, the 

minimum distances given in figures 6 and 7 or in 

the railing's instructions for installation must be 

observed.

3.1. Vor der Montage

Lesen Sie die Montageanleitung, bevor Sie den 

Saunaofen installieren. Überprüfen Sie die folgen-

den Punkte:

• 

Ist der zu montierende Saunaofen in Leistung 

und Typ passend für die Saunakabine? 

Die 

Rauminhaltswerte in Tabelle 2 dürfen weder 

übernoch unterschritten werden.

• 

Ist die Netzspannung für den Saunaofen geeig-

net?

• 

Der Montageort des Ofens er füllt die 

in Abb. 5 und Tabelle 2 angegebenen 

Sicherheitsmindest-abstän de. 

ACHTUNG! In einer Sauna darf nur ein Saunaofen 

installiert werden. Der Saunaofen muß so installiert 

werden, daß die Warnanweisungen nach der Mon-

tage leicht lesbar sind.

Der Ofen darf nicht in einer Nische installiert werden!

3.2. Befestigung des Saunaofens an der Wand

1.  Befestigen Sie das Montagegestell mit den dazu 

gelieferten Schrauben an der Wand und beachten 

Sie die in Abb. 5 und 6 und in Tabelle 2 angeführ-

ten  Sicher heits mindestabstände.

ACHTUNG! An den Stellen, an denen die Befesti-

gungsschrauben angebracht werden, muss sich hinter 

den Paneelen als Stütze z.B. ein Brett befinden, in 

dem die Schrauben fest sitzen. Falls sich hinter den 

Paneelen keine Bretter befinden, können diese auch 

vor den Paneelen angebracht werden.

2.  Heben Sie den Saunaofen so auf das Gestell an 

der Wand, daß die Befestigungshaken unten am 

Gestell hinter den Rand des Saunaofenrumpfes 

kommen.

3.  Den Ofen an dem Wand-Montagegestell  mit Hilfe 

der Klammer befestigen.

3.3. Schutzgeländer

Falls um den Saunaofen ein Schutzgeländer gebaut 

wird, muß dies unter Berücksichtigung der in Abb.6 

und 7 oder in der Montageanleitung für Schutzge-

länder angegebenen Mindestsicherheitsabstände 

geschehen.

Table 2. 

Installation details of the heater

Tabelle 2. 

Montageinformationen zum Saunaofen

Heater

Ofen

Output

Leistung

Vaporizer

Verdampfer

Dimensions

Abmessungen

Stones

Steine

Sauna room

Saunakabine

Output

Leistung

Max. vaporisation 

efficiency

Verdampfungs leistung

Width/Depth/

Height

Breite/Tiefe/

Höhe

Weight/

Gewicht

Cubic vol.

Rauminhalt

Height

Höhe

kW

kW

kg/h

mm

kg

max. 

kg

2.3.

min. m³ max. m³ min. mm

KM60SE

6,0

2,0

2,5

400/330/645

16

25

5

8

1900

KM80SE

8,0

2,0

2,5

400/330/645

16

25

7

12

1900

Summary of Contents for KM60SE

Page 1: ...tt ohje Monterings och bruksanvisning f r bastuaggregat Instructions for Installation and Use of Electric Sauna Heater Montage und Gebrauchsanleitung des Elektrosaunaofens Elektrilise saunakerise kasu...

Page 2: ...AR 15 T m asennus ja k ytt ohje on tarkoitettu saunan omistajalle tai saunan hoidosta vastaavalle henkil lle sek kiukaan s hk asennuksesta vastaavalle s hk asentajalle Kun kiuas on asennettu luovuteta...

Page 3: ...re intended for the owner or the person in charge of the sauna as well as for the electrician in charge of the electrical installation of the heater After completing the installation the person in cha...

Page 4: ...3 Kerise v imsus 35 2 4 Saunaruumi h gieen 35 3 PAIGALDUSJUHIS 36 3 1 Enne paigaldamist 36 3 2 Kerise kinnitus seinale 36 3 3 Kaitsebarj r 36 3 4 Juhtimiskeskuse ja anduri paigaldamine 38 3 4 1 Sobili...

Page 5: ...ggregatets funktion bild 1 Viktig information om bastustenar Du beh ver ca 20 kg mindre bastustenar diameter 5 10 cm Anv nd bara kantiga bastustenar med brutna ytor som r avsedda att anv ndas i ett ag...

Page 6: ...r i botten av aggregatet och byt ut stenar vid behov P det h r s ttet s kerst ller du att ag gregatets badegenskaper bibeh lls och att ingen risk f r verhettning uppst r 1 2 Uppv rmning av bastu F rst...

Page 7: ...ren i samband med uppv rm ningen Den b sta fukthalten uppn s om man st ller in bastutemperaturen p en l g niv ca 40 C fukthalten p en h g niv max 95 och l ter aggregatet och luftfuktaren v rma upp bas...

Page 8: ...a peitt 1 5 Torkning av basturummet Basturummet skall alltid torkas omsorgsfullt efter att nggeneratorn har anv nts F r att p skynda tork ningen kan bastuaggregatet h llas p kopplat sam tidigt som man...

Page 9: ...a Kiukaan osien l mp laajeneminen saattaa aiheuttaa nt kiukaan l mmetess 1 9 Fels kning Allt servicearbete m ste l mnas till professionell underh llspersonal Om nggeneratorn inte fungerar kontrollera...

Page 10: ...neet kest v t huonosti l mp kiukaan kivist mureneva ja ilmavirtauksien mukana nouseva hienojakoinen kiviaines 2 1 Bastuns konstruktion A Isoleringsull tjocklek 50 100 mm Bastun b r isoleras omsorgsful...

Page 11: ...gsna kalkfl ckar fr n aggregatet med 10 citronsyrel sning och sk lj Kuva 4 Bild 4 2 2 Saunahuoneen ilmanvaihto Saunahuoneen ilman tulisi vaihtua kuusi kertaa tunnissa Kuvassa 4 on esimerkkej saunahuon...

Page 12: ...de saker Aggregatets effekt r l mplig med tanke p bastuns storlek De volymer som anges i tabell 2 f r inte verskridas eller underskridas Driftsp nningen r den r tta f r aggregatet Placeringen av aggre...

Page 13: ...tt kumikaapelityyp pi H07RN F tai vastaavaa HUOM PVC eristeisen joh don k ytt kiukaan liit nt kaapelina on kielletty sen l mp haurauden takia Jos liit nt tai asennuskaapelit tulevat saunaan tai saunan...

Page 14: ...l mp tila esim SSJ Yli 1 000 mm korkeudelle saunan lattiasta asennettavien s hk laitteiden tulee olla hyv k syttyj k ytett viksi 125 C ymp rist l mp ti lassa merkint T125 3 5 1 S hk kiukaan eristysre...

Page 15: ...0 8 kW 3 3 H yrystinvastus koottu nggenerators v rmeelement monterad ZH 104 1 4 Vesis ili koottu Vattenbeh llare monterad ZH 70 1 5 Tyhjennysputki koottu Avtappningsslang monterad ZH 110 1 6 Hana Kron...

Page 16: ...at eine gro e Aus wirkung auf die Effizienz des Ofens Abb 1 Wichtige Informationen zu Saunaofensteinen Sie brauchen ca 20 kg kleinere Steine Durchmesser 5 10 cm Verwenden Sie nur spitze Saunasteine mi...

Page 17: ...taub und Gesteinssplitter aus dem unteren Teil des Saunaofens und ersetzen besch digte Steine Hierdurch bleibt die Heizleistung des Ofens opti mal und das Risiko der berhitzung wird vermie den 1 2 Erh...

Page 18: ...to a hot steamer Do not pour fragnances into the water reservoir 1 5 Drying the Sauna Room The sauna room must always be allowed to dry thoroughly after the steamer has been used In order to speed up...

Page 19: ...rations must be done by professional maintenance personnel Saunaofen sich nach der eingestellten Zeit von selbst abschaltet 1 6 Reinigung des Verdampfers Im Wassertank des Verdampfers lagern sich Veru...

Page 20: ...e die folgenden Punkte Befindet sich gen gend Wasser imTank s Abschnitt 1 3 Ist die Saunafeuchtigkeit zu hoch Achten Sie darauf dass derThermostatf hler des Wassertanks oberhalb der Heizspiralen und d...

Page 21: ...ramik und dunkle Zementschl mme verwenden Aus den Sau nasteinen entweichende Partikel und Verunrei nigungen im Wasser k nnen sensible B den verf rben oder besch digen ACHTUNG Fragen Sie die Beh rden w...

Page 22: ...2 4 Sauna Room Hygiene Bench towels should be used during bathing to prevent sweat from getting onto the benches The benches walls and floor of the sauna should be washed thoroughly at least every si...

Page 23: ...p passend f r die Saunakabine Die Rauminhaltswerte in Tabelle 2 d rfen weder bernoch unterschritten werden Ist die Netzspannung f r den Saunaofen geeig net Der Montageort des Ofens er f llt die in Abb...

Page 24: ...und Installation des F hlers alle Abmessungen in Millimetern Figure 6 Location of the mounting rack of the heater Abbildung 6 Platz des Montagegestells des Saunaofens Figure 7 Safety railing of the he...

Page 25: ...evice 3 4 Anschlu desSteuerger tesunddesF hlers Das Steuerger t enth lt detaillierte Anweisungen f r die Montage des Ger tes an der Wand und f r den Einbau des F hlers Luftzufuhr nicht so anbringen da...

Page 26: ...Output Leistung kW Fuses Sicherungen A min mm B min mm A B min mm KM60SE 6 3 x 10A 5 x 1 5 2 x 1 5 7 x 1 5 KM80SE 8 3 x 16A 5 x 2 5 2 x 2 5 7 x 2 5 Figure 9 Electrical connections Abbildung 9 Elektroa...

Page 27: ...2670 W 230 V ZSK 710 8 kW 3 3 Evaporator heating element assembled Heizelement des Verdampfers montiert ZH 104 1 4 Water reservoir assembled Wassertank montiert ZH 70 1 5 Drain pipe assembled Entleeru...

Page 28: ...lementide kah justumine Peske kividelt tolm maha enne nende ladumist kerisele Palun pange saunakive asetades t hele rge laske kividel kerisesse kukkuda Asetage kivid v imalikult tihedalt rge blokeerig...

Page 29: ...iskamine hk saunas muutub kuumenedes kuivaks Seet ttu on sobiva huniiskuse taseme saavutamiseks vaja leili visata Kuumuse ja auru m ju inimestele on erinev eksperimenteerides leiate endale k ige pa re...

Page 30: ...ng toimige j rgnevalt 1 L litage aurusti v lja 2 Kallake ettevaatlikult k lma vett veepaagi restiosale kust vesi valgub paaki ning jahutab paagis oleva kuuma vee 3 N rutage jahtunud vesi paagist vasta...

Page 31: ...gi seintele koguneb aja jooksul vee lisandeid n iteks lupja mille eemaldamiseks v ib kasutada kodumasinate nt kohvi ja veekeetjate tarbeks m eldud katlakivieemaldajaid vastavalt too te pakendil antud...

Page 32: ...e t hendused Loe paigaldusjuhendist ra kata 1 9 Probleemolukorrad Kogu hooldus tuleb lasta l bi viia asjatundlikul hoolduspersonalil Kui aurusti ei t ta kontrollige kas Veepaagis on piisavalt vett vt...

Page 33: ...et leiliruumi ventilatsioon toimiks igesti 2 2 Voodrilaud v i muu materjal kerise l hedal tumeneb kiiresti Veenduge ohutuskauguste n uetest kinnipidamises 3 1 Veenduge et kivide vahelt ei oleks n ha...

Page 34: ...sest vt tabel 2 Vahe saunalava lemise astme ja lae vahel ei tohiks letada 1200 mm G Kasutage keraamilisest materjalist valmistatud p randakatteid ja tumedat vuugisegu Keriseki videst p rit peened osak...

Page 35: ...sk igu ajal Sauna saab kuivatada ka saunask igu j rel ust lahti j ttes D Kui hu v ljat mbeava on pesuruumis peab saunaruumi ukse all olema v hemalt 100 mm vahe Mehaanline v ljat mbeventilatsioon on ko...

Page 36: ...a 6 antud minimaalseid ohutuskaugusi NB Paigaldusraami kinnituskruvide kohal voodrilaua taga peab kindlasti olema paksem laud v i pruss millesse kruvid tugevasti kinnituksid Lauad v ib kinnitada ka vo...

Page 37: ...A B C D E KM60SE 50 60 10 1100 150 KM80SE 100 90 10 1100 150 E D C C 100 KM60SE KM80SE 5 Joonis 5 Kerise minimaalsed ohutuskaugused ja temperatuurianduri paigaldamine k ik m tmed millimeetrites B C A...

Page 38: ...i seinal henduskarp peab olema pritsmekindel ning selle maksi maalne k rgus p randast ei tohi olla suurem kui 500 mm henduskaabel joonis 8 B peab olema kum miisolatsiooniga H07RN F t pi kaabel v i sam...

Page 39: ...ERATUURIANDURIT LEKUUMENEMISKAITSE TEMPERATUURIANDURIT KERIS ma max 100 W VALGE KOLLANE PUNANE VALGE PUNANE KOLLANE SININE ROHELINE HALL SININE NIISKUSEANDUR NIISKUSEANDUR Mudel V imsus kW Kaitsmed A...

Page 40: ...mendid 2000 W 230 V ZSK 700 6 kW 3 2 2670 W 230 V K tteelemendid 2670 W 230 V ZSK 710 8 kW 3 3 Auruti k tteelement monteeritud ZH 104 1 4 Veepak monteeritud ZH 70 1 5 ravoolutoru monteeritud ZH 110 1...

Reviews: