![background image](http://html.mh-extra.com/html/harvard-bioscience/btx-hybrimune/btx-hybrimune_user-manual_601890015.webp)
15
Hybrimune Hybridoma Production System
Publication 015-1010191 Rev 4.0 • www.btxonline.com
Tools Area
The Tools area is found on the left side of the screen and contains
a set of frequently used function buttons. These functions can also
be accessed from the Toolbar as described above.
Tool Buttons
• Folder Button:
Opens a protocol.
• Disk Button:
Protocol “Save As…” Saves a
protocol under a user specified filename.
• Printer Button:
Prints the Last Protocol Log or
the Log History (user selectable) to a file or printer.
• Electric Field Converter Button:
Opens the
Electric Field Converter application.
• Calculator Button:
The Microsoft Windows
®
Calculator.
• Notepad Button:
Saves the protocol Log
under a user specified filename.
• Exit Button:
Exits the program.
Status Area
This area at the upper right corner of the screen displays up-to-date
information about the system conditions.
Features Enabled
This feature shows that there is proper internal connection of the
system when the box labeled Electrofusion is checked.
System Status
This section shows the current system status. These conditions
frequently change during operation.
CommLink:
This box displays the status of the
RS-232 serial communications link.
OK:
Communications is established and functional.
Error
: There is a problem with the
communications link.
The Toolbar
Across the top-left of the main window is a list of standard
Windows
®
pull-down menus.
File Pull-down Menu
• Open:
Opens a previously saved protocol.
• Save:
Saves the current protocol, overwriting
the file if it had been previously saved.
• Save Protocol As:
Saves the current protocol.
The user is prompted for a filename.
• Log Save As:
Saves the protocol Log. The user
is prompted for a filename.
• Print Log:
Prints the Last Protocol Log.
• Exit:
Exits the program.
Tools Pull-down Menu
• Electric Field Converter:
Application to help
convert between absolute voltages and
electric field.
• Standard Calculator:
The Microsoft Windows®
calculator.
• Quick Pulse:
Runs the open protocol without
additional user input. Pressing F12 achieves the
same result. The software activates Turn HV ON
and START. May be used to run the same
protocol repeatedly. A protocol must be open
for this to work.
• Options:
General options to set sound mode,
auto save, provide communications check, etc.
Help Pull-down Menu
• About:
Shows the BTX logo, software version,
and phone numbers.
Hybrimune
™
System Components & Set-Up