HIGHLANDER II VERTICAL PLATFORM LIFTS:
Install Manual
17FEB2021 | 630-00113 REV C
26
TROUBLESHOOTING
HIGHLANDER II: SECTION 6
Amber
Service is required. Flood Switch was activated.
Amber
Service is required. Lift travel time exceeded average.
Amber
Amber
Service is required. Periodic maintenance limit reached.
Amber
Service is required. Service hour limit reached.
Any [Amber]
Minor fault. Platform function is reduced. Service may
be Required.
[Amber]
[Amber]
[Amber]
Lift is running on backup power and battery is very
low. Platform will only go down.
[Amber]
[Amber]
[Amber]
Lift is on AC power and battery is very low. If lift
transfers to backup power platform will only go down.
Service is Required*.
[Amber]
Motor temperature is hot. Platform will only go down.
[Amber]
[Amber]
Motor is drawing too much current. Platform will only
go down. Service is required.
[Amber]
[Amber]
Safety pan has been triggered. Platform will only go up.
[Amber]
Float switch has been triggered. Platform will only go
up. Service will be required to ensure safe operation.
Alarm will turn into a Major Fault after 25 full cycles or
two (2) weeks time after flood event.
[Amber]
[Amber]
Motor temperature monitoring lost. Service is
required.
Any Red
Safety switch triggered. Lift will not function.
Red
Red
A landing door/gate is open. Lift will not function until closed.
Red
Red
A landing door/gate lock has failed. Lift will not
function until lock is enabled. Service may be required.
Red
Red
Red
Red
E-Stop button is pressed. Lift will not function until
button released.
STATUS LED
STATUS
#1
#2
#3
#4
*If battery is not replaced promptly after this warning, the battery will further degrade to the point that unit will shut off completely
when AC power is lost.