HIGHLANDER II VERTICAL PLATFORM LIFTS:
Install Manual
17FEB2021 | 630-00113 REV C
27
TROUBLESHOOTING
HIGHLANDER II: SECTION 6
Red
Red
Red
Pit switch or OSG triggered. If pit switch, lift will not
function until switch changes state. Service is required if
it is the OSG switch.
Any [Red]
Lift will not function. Major Fault. Service is required.
[Red]
Lift out of service. Service is required after a flood
event.
[Red]
[Red]
[Red]
Lift out of service. Service is required for periodic
maintenance.
[Red]
Lift out of service. Lift travel time exceeded average by
2X. Service is required.
[Red]
[Red]
[Red]
[Red]
Lift out of service. Safety nut switch is triggered.
Service is required.
[Red]
[Red]
[Red]
Lift out of service. Final limit switch is triggered. Service
is required.
[Red]
Lift out of service. Top landing switch did not change
state when platform should have moved off landing.
Service is required.
[Red]
[Red]
Lift out of service. Mid landing switch did not change
state when platform should have moved off landing.
Service is required.
[Red]
[Red]
Lift out of service. Bottom landing switch did not
change state when platform should have moved off
landing. Service is required.
[Red]
[Red]
Lift out of service. Motor current is 0 Amps while going
up. Service is required.
[Red]
Lift temporarily out of service. Motor temperature
is Very Hot. Lift will not function until the motor has
cooled.
STATUS LED
STATUS
#1
#2
#3
#4
*If battery is not replaced promptly after this warning, the battery will further degrade to the point that unit will shut off completely
when AC power is lost.