HIGHLANDER II VERTICAL PLATFORM LIFTS:
Install Manual
17FEB2021 | 630-00113 REV C
30
TROUBLESHOOTING
HIGHLANDER II: SECTION 6
The control board has 32 LEDs to provide the status of power to the board and each circuit that is monitored. It
shows the location and description of each LED. See Figure 6-4.
Figure 6-4
4X Bi-Color
Indicator LEDs
26X Green Circuit
Status LEDs
3.3V Power LEDs
24V Power LEDs
DESCRIPTION
COLORS
STATUS, TROUBLESHOOTING
4X Indicators
Green,
Amber,
Red
These LEDs exactly duplicate the Indicator LEDs on Top Cap. If they do
not match there could be an issue with cable or Indicator Board. Refer
to Troubleshooting codes above.
3.3V Power
Green
LED ON indicates processor is getting power.
24V Power
Green
LED ON indicates all 24V circuits are getting power.
E-Stop
Green
LED ON indicates the E-stop is not depressed (lift can run)