background image

HIGHLANDER II VERTICAL PLATFORM LIFTS:

 

Install Manual

17FEB2021  |  630-00113 REV C

34

TROUBLESHOOTING

HIGHLANDER II: SECTION 6

SERVICE MOMENTARY SWITCH
The SERVICE switch should only be used during 

installation and for service by authorized 

technicians.

Pressing the SERVICE switch puts the lift into a 

“Service Mode” which temporarily ignores most 

safety circuits and major faults allowing the 

technician to move the platform and troubleshoot 

issues more easily. All four (4) Indicator LEDs will 

flash green when the unit is in “Service Mode” 

and the lift will automatically go back to normal 

operation after 10-minutes. You can hit the RESET 

switch to exit “Service Mode” before 10-minutes. All 

status LEDs on the control board will work normally 

in “Service Mode.”
Pressing the SERVICE will allow the platform to move 

if the unit is in “Out of Service Mode”, however the 

lift will return to “Out of Service Mode” when the 

“Service Mode” expires. 
To reset the “Out of Service Mode” flag and 

clear memory/errors after required service has 

completed:

1.  Enter “Service Mode” by pressing and    

 

releasing the SERVICE switch.

2.  Press and hold the SERVICE switch for at  

 

least 3 seconds then release.

3.  Press and release the RESET switch within  

 10-minutes.

PERMANENT CUTTABLE JUMPERS
Three permanent cuttable jumpers are included 

on the Control Board that allow the software 

characteristics to change based on configuration.  

If needed these jumpers are cut in the factory and 

should never need to change.
3-STOP JUMPER
This jumper is cut in the factory on 3-stop lifts.  The 

control board will ignore any mid landing circuits 

when this jumper is intact.
TG JUMPER (UNUSED)
In the future this jumper will be used on Toe-Guard 

lifts.
AUX JUMPER (UNUSED)
This jumper could be used for future expansion/

features.

 

GEARMOTOR

The VPL uses a 2/3 Hp gearmotor mounted to the top 

of the tower frame.  The brake on the back of the 

gear motor is a “fail safe,” electromagnetic holding 

brake. The Motor Gearbox on the front of the motor 

is a vented 26:1 worm drive gear reduction with 

synthetic gear and bearing oil.  

See Figure 6-6 on page 35.

Motor is designed for a duty cycle of 25% with a 

maximum continuous operation of 45-minutes.  In 

other words, 45-minutes of continuous operation 

must be followed by 2-hours and 15-minutes of 

rest to prevent possible motor damage. Motor 

temperature is monitored by a thermocouple inside 

the motor housing. If the motor gets too hot it 

could restrict travel of platform to DOWN only.  If 

the motor gets so hot that it could cause damage 

to the motor it will restrict platform movement 

entirely. Platform movement will be restored 

after temperatures fall below hot temperature 

thresholds. See STATUS CODES section for the codes 

displayed. 

Pressing this switch results in the disabling of 
safety circuits. 

WARNING

!

Do not reset the "Out of Service Mode" flag until 
required service has been performed. Unsafe 
operation could result. 

WARNING

!

Summary of Contents for HIGHLANDER II

Page 1: ...17FEB2021 630 00113 REV C HIGHLANDER II VERTICAL PLATFORM LIFT INSTALLATION SERVICE MANUAL...

Page 2: ......

Page 3: ...ay No Floor Penetration 12 Electrical Connection 12 Battery Backup 13 Platform Connection 14 Installing the Platform Control Guard Panel 14 Installing a Platform Gate If Equipped 14 Installing the Pla...

Page 4: ...conditions that jeopardize the technician s safety or ability to complete the installation in a safe manner Tents canopies or other outdoor provisions that help protect the work area from weather or...

Page 5: ...ns on the particular lift model and configuration CODE STATEMENT The Harmar Highlander II lift has been designed to meet ASME A18 1 Safety Standard for Platform Lifts and Stairway Chairlifts under sec...

Page 6: ...r must comply with 2 1 1 and with the building code NOTE There are 3 different sections of rules for a commercial application 2 1 1 Runway Enclosure Provided 2 1 2 Partial Runway Enclosure Provided 2...

Page 7: ...HIGHLANDER II SECTION 2 KEY VERTICAL PLATFORM LIFT ELEMENTS 1 Top Cap 2 Lift Status Indicator Lights 3 Data Serial Tag 4 Platform 5 Platform Side Panel 6 Grab Rail if supplied 7 Platform Controls 8 P...

Page 8: ...ew 4 Batteries if supplied 5 Battery Charger and assembly tray if supplied not shown 6 Inverter if supplied 7 Control Electronics Assembly 8 Upper Lower Lower Final Limit Switches 9 Tower Frame 10 Tow...

Page 9: ...p Square Level Multimeter Wire Cutters Wire Puller Stripper Crimping Tool Hammer Drill 3 8 Wrench Set 7 16 1 2 9 16 3 4 Allen Wrench 1 8 3 16 5 16 Torx Wrench T20 No 1 Phillips Head Screwdriver No 2 F...

Page 10: ...cated Electrical Lead per local code UNLOADING The 4 VPL is shipped standing up shrink wrapped to a pallet The pallet dimensions are 48 x 48 x 83 Units are screwed into the pallet installers will requ...

Page 11: ...Care should be taken not to scratch or damage panels when removing carrying and reinstalling them Special care must be taken to protect any landscaping or flooring surfaces that might be damaged by t...

Page 12: ...should only be lifted by the rectangular tubes below the top plate ELECTRICAL CONNECTION 1 Remove and discard the temporary bolt and nut 9 16 hex that secures the tensioning pulley to the carriage fo...

Page 13: ...d route down through the back of the center wire channel to the bottom of the lift and out to a temporary 120V AC outlet See Figure 4 5 Junction box Back brace of tower Wire channel Figure 4 5 5 Once...

Page 14: ...ntrol side guard panel posts into the pockets on the platform with the smooth side facing the inside of the platform Fasten in place with four 4 1 4 20 x 2 bolts Torque bolts down sufficiently to hold...

Page 15: ...he guard panel post and thread into the platform NOTE If a platform gate is equipped the pivot tabs mount to the face of the gate with different hardware and nuts 2 Assemble the ramp roller arm into t...

Page 16: ...wiring to a landing gate See Figure 4 11 for wiring to a call station and strike Figure 4 9 Figure 4 10 Figure 4 11 NOTE If the call send switch is installed in the gate the wires are routed between...

Page 17: ...when the wiring is corrected NOTICE 10 Reinstall interlock gate post covers and hole plugs NOTE Gates are field reversible contact Harmar Technical Service for instructions FASCIA PANEL INSTALLATION...

Page 18: ...gang outlet box 1 Remove four 4 label plate screws and label plate See Figure 4 15 Back Cover Front Cover 4 Cover Screws Label Plate Key Lock optional Figure 4 15 2 Remove four 4 cover screws and the...

Page 19: ...ls please refer to the supplemental guide Highlander II Wiring Schematics NOTE A wiring diagram with part number 640 00025 is placed in a packet with your shipment NOTE Von Duprin strikes are not comp...

Page 20: ...Apply temporary power and verify all four 4 LED indicator lights on the control board are solid green Manually depress the final limit switch the highest positioned switch and verify any travel of pla...

Page 21: ...t the top cap Reconnect the power to the lift OPERATIONAL CHECK Upon installation and at scheduled intervals the operation of the VPL must be verified NOTE ASME A18 1 2017 requires that when the lift...

Page 22: ...15 Amp breaker The fuses should be a minimum of 15A See Figure 4 18 OUTSIDE TOWER CONDUIT DPST FUSED DISCONNECT G G N L S L INSIDE TOWER JUNCTION BOX 5X WIRE NUTS Figure 4 18 Route wiring from disconn...

Page 23: ...ications this would take place with any or all of the following the property owner facilities manager or any personnel who may oversee the unit s use or control its access PROVIDE OVERVIEW Review all...

Page 24: ...se 2 x4 beneath platform base when connecting to carriage INSTALL LANDING GATE Screw to Landing Pre run Wiring INSTALL FASCIA PANEL Attach to Open Areas Under Gate Ensure Smooth Flush No Gaps Protrusi...

Page 25: ...flashing light STATUS LED STATUS 1 2 3 4 All OFF Lift will not function Major Fault No Power and no battery or Low Power Mode Service is Required Any Green or Green Lift functional No faults Green Gr...

Page 26: ...Amber Motor is drawing too much current Platform will only go down Service is required Amber Amber Safety pan has been triggered Platform will only go up Amber Float switch has been triggered Platfor...

Page 27: ...d Lift out of service Final limit switch is triggered Service is required Red Lift out of service Top landing switch did not change state when platform should have moved off landing Service is require...

Page 28: ...ONICS If the Indicator LEDs do not provide enough information to fully troubleshoot a potential issue it may be necessary to access the control electronics below the top cap of the tower Access the co...

Page 29: ...outputs on the Control Board See Figure 6 3 Figure 6 3 Indicator Board Connector Alarm Connector 3A Circuit Breaker Screw Terminal Motor Thermocouple Connector Brake Connector Down Contactor Connector...

Page 30: ...Indicator LEDs 26X Green Circuit Status LEDs 3 3V Power LEDs 24V Power LEDs DESCRIPTION COLORS STATUS TROUBLESHOOTING 4X Indicators Green Amber Red These LEDs exactly duplicate the Indicator LEDs on T...

Page 31: ...en LED ON indicates the Up button in the Bottom Call Station is being depressed Down Bottom Green LED ON indicates the Down button in the Bottom Call Station is being depressed Bottom Gate Green LED O...

Page 32: ...re 11 safety pan switches in platform Bottom Land Green LED ON indicates the Bottom Landing switch is closed The switch should be closed only when platform is at that landing Float Switch Green LED ON...

Page 33: ...check brake operation and is recommended to be used in the emergency lowering procedure RESET MOMENTARY SWITCH Pressing the RESET momentary switch will reset the processor and exit Service Mode if boa...

Page 34: ...cs to change based on configuration If needed these jumpers are cut in the factory and should never need to change 3 STOP JUMPER This jumper is cut in the factory on 3 stop lifts The control board wil...

Page 35: ...tor is engaged after the motor comes to a stop If the platform is taking too long to come to a stop there could be an issue with this resistor or the wiring on it LOAD RESISTORS The load resistors fun...

Page 36: ...urn to a full charge BATTERY CHECK RELAY Since we cannot check battery voltage while the battery is charging we have a Battery Check Relay that switches between charging and voltage monitoring The bat...

Page 37: ...they should follow the Emergency Lowering Procedure to evacuate the occupant EMERGENCY LOWERING PROCEDURE In the event that the lift becomes disabled with passengers on the platform that is not at a...

Page 38: ...atform from drifting with heavy loads Lowering the platform with the brake engaged will require a bit of strength typically the equivalent of being able to lift 20 lb with one arm 6 If the lift has po...

Page 39: ...the built in safety device designed to detect obstructions under the platform and stop platform downward motion If there is an easy to remove obstruction please remove it If for any reason the safety...

Page 40: ...t and legible If any safety or warning labels need to be replaced please contact your dealer Make sure you have a copy of the Owner s Manual A digital copy of the Owner s Manual is available at harmar...

Page 41: ...HIGHLANDER II VERTICAL PLATFORM LIFTS Install Manual 17FEB2021 630 00113 REV C 41 NOTES HIGHLANDER II...

Page 42: ...HIGHLANDER II VERTICAL PLATFORM LIFTS Install Manual 17FEB2021 630 00113 REV C 42 NOTES HIGHLANDER II...

Page 43: ...HIGHLANDER II VERTICAL PLATFORM LIFTS Install Manual 17FEB2021 630 00113 REV C 43 NOTES HIGHLANDER II...

Page 44: ...2075 47th Street Sarasota FL 34234 800 833 0478 harmar com...

Reviews: