Micro Series
1-76 Micro Series
Document generated: 04.10.17
SW V1.2
The GPI tab is the page where all general purpose input functions are con-
figured and activated.
1 [2]
[3]
[ ]
[ ]
[ ]
[1]
On/Off
Lets the operator activate the GPI. The button is illuminated when active.
[2]
Dir
The Polarity of the signal at the input pin: High=Active is positive-,
Low=Active is negative polarity.
[3]
Sensitivity
Considering the polarity, the sensitivity defines whether the input function
reacts on
Rising
edge,
Falling
edge or
Level
changes.
[4]
Action
Action is only relevant, if sensitivity is falling edge or rising edge. In this case,
it defines if the input function activates (Activate), deactivates (Deactivate)
or toggles (Alternate) the parameter value. Usually Action is set to Alternate.
Activate and Deactivate are used in case where two GP Inputs for the same
GPInput Function are available, e.g. ON button and OFF button.
[4]
Time
Defines the time a pulse at the input pin must have at least to be interpreted
as momentary. Time is only relevant if Sensitivity is Level.
Time = 0 : Momentary only. Set the parameter according to Level
Time > 0 : Momentary and Latching. Momentary (if level is active for more
ms than Time). Set parameter value according to Level. Latching (if level is
active less for less ms than Time) toggle the parameter value (on falling edge)
If the pulse is shorter than the specified Time, the Function is latched.