The following table shows all output functions :
Function
Argument 1
Argument 2
Argument 2
Description
CHANNEL ON
Channel1..12
Send1..4
Reflects the On/Off status of channels and sends.
CHANNEL PFL
Channel1..12
Send1..4
PRG, REC
Reflects the PFL On/Off status of channels, send and
FADERSTART
Channel1..12
Reflects the AND combination of channel’s
On/Off- and fader status.
FADPFL
Channel1..12
Same as FADERSTART, but also active when chan-
nel’s PFL is active. (FADERSTART OR PFL.)
CHANNEL ON MASTER
Channel1..12
The function becomes active when the specified
channel is either on PRG or REC output.
(Channel On-Master condition)
RedLight Studio
The function becomes active when a microphone is
either on PRG or REC output.
In other words, at least one channel with role DJ
or Guest fulfils the Channel On-Master condition.
ONAIR
The function becomes active when at least one chan-
nel is OnAir.
RECORD
The function becomes active when at least one chan-
nel is on the REC output.
One of the the following conditions must be fulfilled
for at least one channel:
AND
the fader is open
AND
the channel is assigned to REC bus
AND
the REC fader is open
AND
the fader is open
AND
Off Air Record is active on the channel
AND
the REC fader is open
TALKBACK
Source :
TBfromANY
TBfromCH1..12
TBfromEXTERN
Destination :
TBtoANY
TBtoCR
TBtoDJ
TBtoGUEST
TBtoSend1..4
TBtoEXTERN
The function becomes active when TB from Source to
Destination is active.
The GPOutput can be used to control external
intercom systems for TB button illumination.
The function does not indicate incoming
TB.
CR MON SRC
PRG, REC
Send1..4
EXTERN
PFL
The function becomes active when the specified
monitoring source is currently active on the CR moni-
toring.
GUEST MON SRC
PRG, REC
Send1..4
EXTERN
FOLLOW CR
The function becomes active when the specified
monitoring source is currently active on the Guest
monitoring.
PFL ACTIVE
The function becomes active when any channel PFL
is active.