Table 2-23 Set trigger mode to pulse trigger function menu 1:
Option
Setting
Introduction
Type
Alternative
The trigger signal comes from two vertical channels
when you use alternative trigger. In this mode, you
can observe two irrelative signals at the same time.
Source
CH1
CH2
Set trigger type information for CH1 signal
Set trigger type information for CH2 signal
Mode
PulseSet trigger type of the vertical channel
signal to Pulse trigger.
When
Select how to compare the trigger pulse
relative to the value selected in the Set Pulse
Width option.
Next Page
Page 1/2
Enter the second page of Alternative
trigger menu.
Option
Setting
Table 2-24 Set trigger mode to pulse trigger function menu 2:
Explain
Set Width
20.0ns
~10.0s
Selecting this option can turn the universal
to set up the pulse width.
Set up
Enter the Trigger Setup Menu
(see table 2-14).
Next Page
Page 2/2
Press this button to return the first page.
Option
Setting
Introduction
Type
Alternative
The trigger signal comes from two vertical
channels when you use alternative trigger.
In this mode, you can observe two irrelative
signals at the same time.
Source
CH1
CH2
Set trigger type information for CH1 signal
Set trigger type information for CH2 signal
Mode
Video
Set trigger type of the vertical channel signal
to Video trigger.
Polarity
(Normal)
(Inverted)
Normal triggers on the negative edge of
the sync pulse.
Inverted triggers on the positive edge of
the sync pulse.
Next Page
Page 1/2
Enter the second page of Alternative trigger menu.
Table 2-25 Set trigger mode to video trigger function menu1:
Option
Setting
Introduction
Table 2-26 Set trigger mode to video trigger function menu 2:
Sync
Line Num
All lines
Odd field
Even Field
Select appropriate video sync.
Standard
NTSC
Pal/Secam
Select the video standard for sync and
line number count.
Next Page
Page 1/2
Enter the second page of Alternative trigger menu.
42
Digital
S
torage
O
scilloscope
Digital Storage Oscilloscope
43