end, unscrew the dust cover on the intake stop valve, insert the filling plug, open the intake stop valve
for filling, and take out the filling plug when the LPG quantity reaches 80% of steel cylinder volume
(when filling to 80% of rated capacity, the limit device will be automatically closed). Pull out the filling
plug, screw the dust cover of the filling valve, and tighten the intake limit valve when the charge stops.
Check whether the components at each location are in good condition.
(4) You should lift the steel cylinder on the truck and fix the cylinder firmly with the arrow (5) pointing
up. You should insert the dowel pin into the steel cylinder.
(5) You should ensure that the intake and outlet stop valves (4,8) are closed.
(6) You should connect the forklift truck pipe joint (10) with the outlet joint (9) and fasten them.
(7) You should slowly open the stop valve (8) at the outlet end.
(8) You can use the stop valve after confirming that there is no leakage, close the stop valve (8) at the
outlet end immediately if there is leakage, and unscrew the interface (3) at the inlet end of the forklift
truck.
Note: Open the stop valve (8) at the outlet end of the steel cylinder after installing the steel cylinder
and connecting the quick coupling with the connecting line and apply soap bubbles to each pipe joint
to check for air leakage; if air leakage is found, the forklift truck can only be started after
troubleshooting. Please close the stop valve (8) at the outlet end after using the forklift truck each
time.
10. How to mount the steel cylinder:
Steel belt bracket
11
3
2
1
4
6
7
8
5
9
10