The Plume Diverter terminal must not under
any circumstances deflect flue products
downwards.
3i
The diverter allows the terminal clearance to be reduced as follows
(see diagrams below):
Clearance H – From a surface facing the terminal - 600mm.
Clearance F – From internal or external clearances - 300mm.
b)
Choose the direction required to deflect the flue products
(left or right only)
c)
Push the diverter elbow onto the angled outlet of the flue
terminal in the desired rotational position and ensure the diverter
is pushed up to the shoulder to fully engage the rubber seal.
d)
Fix the diverter to the flue terminal with the self drilling screw
provided.
Do not use a power tool to fit screw.
2.9
APPLIANCE HYDRAULIC CIRCUITS
4a
Central Heating Mode (CBX)