LED CODE
FAULT/EFFECT
REASON
ACTION
1 2 3 4
G
Check no air is in heat exchanger/CH system
G
Check pump operation
HHHG
Overheated appliance
Water temperature greater than 105 °C
G
Check diverter valve operation
G
Check PCB/X1C connector
G
Check mains lead to pump
G
Check flow thermistor
G
Check gas supply
HHGH
No gas/No flame
Low gas pressure
G
Check gas service cock
G
Check gas valve and lead
G
Check detection electrode/lead
HHGG
Lockout flame signal/
No flame signal on ignition, or loss
G
Check gas supply
Lockout after 5 ignition
of signal during operation
G
Check gas valve and lead
attempts
G
Check PCB/X2A & X2B connectors
G
Check spark generator/spark electrode
G
Check mains earth lead continuity
G
Check flue sensor
HGHH
Flue gas sensor/
Flue gas temperature greater than 95 °C
G
Check flue system
No flame
G
Check no air is in heat exchanger/CH system
G
Check pump
G
Check PCB/PCB connectors
HGHG
Defective sensor/
Defective flow, return or flue sensor
G
Check flow, return and flue sensors
No flame
G
Check wiring to sensors
G
Check PCB/X6 & X8 connectors
HGGH
Defective gas valve/
5 sec flame signal after
G
Check gas valve and lead
Flame continues after
burner is switched off
G
Check PCB
demand ends
G
Check fan
G
Check mains fan lead & connector
HGGG
Defective fan/No flame
Missing or Erroneous RPM signal
G
Check low voltage fan lead & connector
G
Check PCB/X3 connector
G
Check pump operation
G
Check diverter valve operation
GHHH
CRC error/No flame
Internal Eprom data error
G
Check PCB
GHHG
Error in power supply/
Low mains voltage
G
Check mains voltage
No flame
G
Check PCB connectors
G
Check water pressure
GHGH
Water flow failure/
G
Check pump
Flame for a short
Sensor temperature differential incorrect
G
Check no air is in heat exchanger/CH system
period only
G
Check flow, and return sensors
G
Check wires to sensors not crossed
GHGG
PCB error/No flame
Internal error
G
Check PCB
GGHH
BCC error/No flame
Incorrect /missing BCC
G
Reseat or replace BCC
GGHG
Differential check faulty/
G
Check flow, and return sensors
Flame for 15 seconds
Zero check faulty DHW or CH
G
Check wires to sensors not crossed
G
Check PCB
GGGH
Activate BCC/No flame
New BCC
G
Press reset to activate
GGGG
Safety system failure/
Failure of internal self checking system
G
Check PCB
No flame
G
Check DHW turbine & lead
HHHH
DHW cold
Defective DHW turbine or Diverter valve
G
Check Diverter valve & lead
G
Check PCB/X4 connector
G
Check filter in plate heat exchanger
G
Check power supply
HHHH
No light indication
Defective power supply
G
Check PCB/X1B connector
G
Check PCB fuse
HHHH
No flame
Faulty connector
G
Check PCB/X1A connector
31
Summary of Contents for Eden CBX
Page 13: ...4b Domestic Hot Water Mode CBX 4c Central Heating Mode SBX 11...
Page 28: ...26 24 CBX SBX...
Page 31: ...INTERNAL WIRING DIAGRAMS 7 7 1 FUNCTIONAL FLOW WIRING DIAGRAM 29 29...
Page 44: ...42 54 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24...
Page 45: ......
Page 46: ......