4
2.4
OVERALL DIMENSIONS AND MINIMUM CLEARANCES
1
200mm
200mm
366mm
760mm
455mm
914mm
150mm
97mm
228mm
100mm Ø
5mm
SEE NOTE
5mm
NOTE:
10mm for normal
operation.
450mm for installation
and servicing.
The EDEN 'x-type' range can be installed to a number of different
concentric flue systems. The different flue applications as shown in
Figure 2 are available as kits usually comprising the connecting
parts to the appliance and end terminal. Flue extension ducts and
extension elbows are available as accessories.
2.5
CONCENTRIC AIR / FLUE DUCT SPECIFICATIONS
Connections
CBX32
CBX24
SBX30
CBX38
Gas
15 mm compression
22 mm compression
CH flow
22 mm compression
CH return
22 mm compression
DHW inlet
CBX appliance only
15 mm compression
DHW outlet
CBX appliance only
15 mm compression
DHW return
SBX appliance only
22 mm compression
Pressure relief valve outlet
15 mm tail
Condensate Drain
21.5 - 22 mm plastic overflow pipe