HEAT EXCHANGER
6.5
COMBUSTION CHAMBER &
Inspect the inside of the combustion chamber for debris. If
necessary, clean the inside of the tubes with a soft brush. Do not
brush the insulation at the rear, check the integrity of the
combustion chamber insulation panels, if damaged they will
require replacement.
6.6
CONDENSATE DRAIN
The condensate Drain has a removable cap, Figure 27, which
allows the removal of debris that may be caught within it. Place a
bowl under the cap to catch the condensate and remove the cap.
Any debris inside will be expelled at this point. Replace the cap
ensuring a good seal is made. Discard the condensate and debris.
25
GAS CONTROL VALVE, FAN & BURNER ASSEMBLY
26
26A SPARK ELECTRODE
26B DETECTOR ELECTRODE
FILTER (CBX APPLIANCES ONLY)
6.7
DOMESTIC COLD WATER INLET
Close the water inlet isolating cock, open a domestic hot water tap
at the lowest point in the system and allow the pressure to
dissipate. Close this tap again. Undo the nut holding DHW turbine
to the water inlet isolating cock. The filter inside the isolating cock
can now be carefully removed, and cleaned as necessary by
flushing with water. Re-assemble in reverse order, ensuring all
seals are replaced correctly. Refer to Figure 28
27
Summary of Contents for Eden CBX
Page 13: ...4b Domestic Hot Water Mode CBX 4c Central Heating Mode SBX 11...
Page 28: ...26 24 CBX SBX...
Page 31: ...INTERNAL WIRING DIAGRAMS 7 7 1 FUNCTIONAL FLOW WIRING DIAGRAM 29 29...
Page 44: ...42 54 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24...
Page 45: ......
Page 46: ......