18 June 2016
X6-ElectroMod
A 160AH 1.5KW Electrical Power Generator for the BMW X6
pg. 22
Copyright © 2016, HallonPower. All content and images presented on this website are copyrighted © and all rights are reserved.
All manufacturer names, symbols, and descriptions, used in our images and text are used solely for identification purposes only. It is neither inferred nor
implied that any item sold here, is a product authorized by or in any way connected with any vehicle manufacturers displayed on this page. This document
may be modified at any time and without notice.
C. Cable Harness
1.
Pass the cable harness (LOOM1, LOOM2, C14) under the trunk floor and into the area where
the Interior-Rear-Storage Compartment Right (C) used to sit.
2.
Take the Interior-Rear-Storage Compartment Right (C) and pass each cable through the hole
we opened on its front. When all cables (Inverter power cable, Inverter remote cable,
LOOM1, LOOM2, C14) have been inserted, lower the Interior-Rear-Storage Compartment
Right (C) back into position. Leave the cables loose there for now.
D. Chassis GND
1.
Find the car's grounding bolt on the rear wall of the trunk floor compartment and unscrew
it.
CAUTION: Do not remove the cables connected, or your car will reset. This is not a big deal if
it happens though. You may just have to re-set some of your settings like the time etc.
2.
Take the chassis grounding cable from the Grounding Bus Bar (BB-CHA/GND) and the
SBB -ve cable (SBB/N-CHA/GND - 19cm 2AWG black) and bolt them on top of any cables
already present here.
E. Power Distribution Vertical Panel
1.
Make sure all cables are collected to the right side of the trunk floor compartment and then,
take the Power Distribution Vertical Panel, with all its brackets already attached, lower it
into position and fasten it temporarily with a couple of screws.
Please note: Before you proceed, make sure your trunk floor door can be closed properly. If
you find that the trunk floor door needs a lot of effort to close properly, then you need to
recheck your installation for problems. If you have followed closely the above steps, there
should be no problems closing the floor door.
2.
If all is well, take a marker and mark a spot on the rear wall of the trunk floor, where a hole
should be drilled to fasten the rear bracket of the Power Distribution Vertical Panel. Apply
enough force onto the top part of the Power Distribution Vertical Panel until it sits at its
lowest level. (You may need to remove the Power Distribution Vertical Panel in order to drill
the hole, otherwise go ahead).
3.
Once the hole is drilled finish fastening the Power Distribution Vertical Panel to the SP and
the rear of the trunk floor compartment wall.
Please note: Recheck and make sure your trunk floor door can be closed properly.