31-5000751 Rev. 0
Compressor Equalization Valve
The compressor equalization valve equalization solenoid equalizes the pressure across the rotary compression chamber
allowing the compressor to start unloaded. The 240 VAC solenoid coil is controlled by the inverter. The solenoid coil is
powered when the compressor is off to equalize the pressure and is de-energized when the compressor is operating.
STATUS CODES:
When the compressor is running, the 7-segment display will show the compressor capacity. When the NS18HM unit is
installed with a conventional 24VAC thermostat the display will show C 1 or C 2.
Figure 30.