107
R25=10kΩ±3% B25/50=3700K±3%
Temp
Resistance (kΩ)
% (Resist. Tol)
(°C)
Rmax
R (t) Normal
Rmin
MAX (+)
MIN (-)
5
24.742
23.687
22.632
4.45
4.45
6
23.61
22.619
21.628
4.38
4.38
7
22.538
21.607
20.676
4.31
4.31
8
21.522
20.647
19.772
4.24
4.24
9
20.559
19.737
18.915
4.16
4.16
10
19.646
18.874
18.102
4.09
4.09
11
18.779
18.054
17.329
4.02
4.02
12
17.958
17.276
16.594
3.95
3.95
13
17.177
16.537
15.897
3.87
3.87
14
16.436
15.834
15.232
3.8
3.8
15
15.731
15.166
14.601
3.73
3.73
16
15.061
14.53
13.999
3.65
3.65
17
14.424
13.925
13.426
3.58
3.58
18
13.817
13.349
12.881
3.51
3.51
19
13.24
12.8
12.36
3.44
3.44
20
12.69
12.277
11.864
3.36
3.36
21
12.166
11.778
11.39
3.29
3.29
22
11.666
11.302
10.938
3.22
3.22
23
11.189
10.848
10.507
3.15
3.15
24
10.734
10.414
10.094
3.07
3.07
25
10.3
10
9.7
3
3
26
9.898
9.604
9.31
3.06
3.06
27
9.514
9.226
8.938
3.13
3.13
28
9.147
8.864
8.581
3.19
3.19
29
8.796
8.519
8.242
3.25
3.25
30
8.459
8.188
7.917
3.31
3.31
31
8.137
7.871
7.605
3.38
3.38
32
7.828
7.568
7.308
3.44
3.44
33
7.532
7.277
7.022
3.5
3.5
34
7.248
6.999
6.75
3.56
3.56
35
6.977
6.733
6.489
3.63
3.63
36
6.716
6.477
6.238
3.69
3.69
37
6.466
6.232
5.998
3.75
3.75
38
6.227
5.998
5.769
3.81
3.81
39
5.997
5.773
5.549
3.88
3.88
40
5.776
5.557
5.338
3.94
3.94
41
5.564
5.35
5.136
4
4
Summary of Contents for AU082FYCRA(HW)
Page 1: ...ATW Service Manual SYJS 03 2019REV A Edition 2019 03 ...
Page 11: ...9 405 410 600 174 174 450 950 965 395 6 Dimensions AU082FYCRA HW Unit mm ...
Page 12: ...10 AU112 162FYCRA HW Unit mm 1490 950 380 187 405 410 600 174 174 450 170 ...
Page 13: ...11 AU082FYCRA HW 7 Piping Diagram ...
Page 14: ...12 AU112 162FYCRA HW ...
Page 27: ...25 12 Water Pressure Drop ...
Page 28: ...26 ...