7-22
SECTION 7 –
SPRAY SYSTEMS
Rolling Boom
The Rolling Boom feature will enable the
boom to roll either “clockwise” or “counter-
clockwise” (as viewed from the cab) using
the Roll Command Buttons (located on the
Machine Display Auxiliary Controls Page).
•
Press and hold the “CW” Roll Command
Button to roll the boom “clockwise”.
•
Press and hold the “CCW” Roll Com-
mand Button to roll the boom “counter-
clockwise”.
NOTE: The Roll Command Buttons will
illuminate when held in the ON
position and the current boom
alignment value will be displayed.
•
When either of the CW or CCW Roll
Command Buttons are released, the
boom will return to the neutral (center)
position.
NOTE: Center position value is 0 inches/cm.
Enabling/Disabling NORAC
®
in
the Pulse Display
-If Equipped
NOTE: Hagie Manufacturing Company
recommends turning the NORAC
Monitor OFF when traveling from
one field to the next. A power switch
is located on the back side of the
monitor.
•
To Enable
, press the corresponding Auto
or Manual Button (located on the main
“Run Screen”) to the ON (green illumi-
nated position).
•
To Disable
, press the corresponding
Auto or Manual Button to the OFF (gray)
position or press any one of the follow-
ing boom control switches (located on
the Hydrostatic Drive Control Handle):
Clockwise
Counter-Clockwise
Roll Command Buttons (CW/CCW)
(Located on the Machine Display
Auxiliary Controls Page)
NORAC Monitor
-Typical View
Auto/Manual Buttons - NORAC
(Located on the main “Run Screen”)
-Typical View
* Your monitor may vary in
appearance, depending on model
Summary of Contents for STS12i Combo
Page 276: ......