186
Pending Power Mode : Not Applicable
Survival Mode : Enabled
--------------------------------------------------------
Cache Properties
--------------------------------------------------------
Cache Status : Ok
Cache Serial Number : Not Applicable
Cache memory : 1808 MB
Read Cache Percentage : 40 percent
Write Cache Percentage : 60 percent
No-Battery Write Cache : Enabled
Wait for Cache Room : Disabled
Write Cache Bypass Threshold Size : 1040 KB
--------------------------------------------------------
Green Backup Information
--------------------------------------------------------
Backup Power Status : No Battery Connected
Battery/Capacitor Pack Count : 0
Hardware Error : No Error
--------------------------------------------------------
Physical Drive Write Cache Policy Information
--------------------------------------------------------
Configured Drives : Disabled
Unconfigured Drives : Disabled
HBA Drives : Disabled
--------------------------------------------------------
maxCache Properties
--------------------------------------------------------
maxCache Version : 4
maxCache RAID5 WriteBack Enabled : Enabled
--------------------------------------------------------
RAID Properties
--------------------------------------------------------
Logical devices/Failed/Degraded : 1/0/0
Spare Activation Mode : Failure
Background consistency check : Idle
Consistency Check Delay : 3 seconds
Parallel Consistency Check Supported : Enabled
Parallel Consistency Check Count : 1
Inconsistency Repair Policy : Disabled
Consistency Check Inconsistency Notify : Disabled
Rebuild Priority : High
Expand Priority : Medium
--------------------------------------------------------
Controller Version Information
--------------------------------------------------------
Firmware : 4.11
Driver : Linux 1.2.10-025
Summary of Contents for UniServer R4300 G6
Page 36: ...21 Figure 23 Selecting the controller and RAID level 4 Select drives and then click Next...
Page 40: ...25 Figure 27 Selecting the RAID array to be deleted 2 In the dialog box that opens click Yes...
Page 66: ...24 Figure 37 Confirming RAID creation 7 Click OK to complete the RAID creation...
Page 164: ...89 Figure 158 Selecting Main Menu 2 Select Controller Management and press Enter...
Page 321: ...90 Figure 138 Configure Controller Settings screen for the RAID P460 B2...
Page 469: ...19 Examples Viewing physical drive informatoin Syntax mnv_cli info o pd Examples...
Page 513: ...7 Figure 10 Selecting Drive Management 4 Select the target drive and then press Enter...
Page 514: ...8 Figure 11 Select the target drive 5 View the value of the Status field...
Page 529: ...23 Figure 33 Identifying a storage controller 2...